10kv Aerial Bundled Cable

Brand Name:OEM
Certification:ISO/RoHS/CE
Minimum Order Quantity:200 meters
Delivery Time:5-15day
Payment Terms:L/C, T/T
Place of Origin:china
Contact Now

Add to Cart

Verified Supplier
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

10kv Aerial Bundled Cable


Type of ABC Aerial Bundled Cable


No.Product TypeApplication
1PVC insulated aerial bundle cableFor aerial power transmission
2PE insulated aerial bundle cable
3XLPE insulated aerial bundle cable
4Steel reinforced aluminum wire with PVC insulated aerial b undle cableFor aerial power transmission, able to bear moderate pulling force.


Production Range of ABC Aerial Bundled Cable


Voltage: 1kv, 10kv, 35kv

No. of cores: 1, 2, 3, 4, 5, 3+1, 4+1, 3+2

Nominal cross sectional area: 10~1500mm2



Construction of ABC Aerial Bundled Cable:


Phase conductor: copper, aluminum, aluminum alloy stranded

Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), Aluminum conductor steel reinforced(ACSR)

Insulation: PVC, XLPE, PE



(Remark: This is just the normal construction. HUANGHE CABLE can also design and produce the cables according to your special requirement.)



Application of ABC Aerial Bundled Cable:


Insulated Single Core Aerial Cable

Covered line wire is used primarily for overhead secondary distribution lines.It is not an electrically insulated conductor and is treated as bare conductor when installed.


Duplex Service Drop Cable

To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 °C maximum.


Triplex Service Drop Cable

To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°Cmaximum for polyethylene insulation or 90°C maximum for cross linked insulation.


Quadruplex Service Drop Cable

Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltage of 600 volts or less phase to phase and at conductor temperature no to exceed 75°C for polyethylene insulated conductor or 90°C for cross linked polyethylene insulated conductors.



600V ABC Aerial Bundled Cable Data


Number of Cores x Nominal Cross SectionOverall DiameterWeightMaximum Conductor ResistanceMinimum Breaking LoadCurrent Rating
No.×mm²mmKg/KmΩ/KmkNA
1x16 RM8,07419102,572
1x25 RM9,010612004,0107
1x95 RM15,43330,32013,7240
1x185 RM21,06110,16428,7389
1x240 RM24,08010,12537,2467
2x16 RM15,614719102,572
2x25 RM18,020812004,0107
2x70 RM25,45050,44310,7205
4x16 RM18,828619102,572
4x70 RM31,81.0090,44310,7205
4x95 RM37,81.3320,32013,7240
4x70 + 1x25 RM36011050,443/1,20010,7/4,0205/107
4x70 + 2x25 RM40012170,443/1,20010,7/4,0

205/107