XLPE Insulation Copper Conductor Low Smoke Zero Halogen Cable


Conductor: Class 2 annealed bare copper solid or strands. This wires are formed into final conductor in the stranding machines under strict quality surveillance.


Screen : Mica tape fire resistant screen


Insulation: Cross linked polyethylene compound or PVC is insulated over the conductors by extrusion process.The raw materials and thicknesses of Insulation are maintained as per standards and conform to IEC60502/BS7870 Standards as the case may be.


XLPE:Insulated Power Cable are identified either by colour or by numbers as follows:
No. of cores Identification
Old Colour coding New Colour coding as per requirement


Outer sheath : Standard cables are manufactured with Extruded black PVC. Outersheath is embossed or printed with the information required by relevant standards.
Special FR, FRLS, FRRT, LSF, MDPE compounds are used for outersheathing of cables, to suit customer’s specific requirements.


Standards

International: IEC 60502, IEC 60227 IEC 60331, IEC 61034

China: GB/T 12706-91 GB306.1-2001, GB/T18380.3-2001

Other standards such as BS,DIN and ICEA upon request


Technical data:


Test voltage 0.6/1 kV [kV] 3.5 / 5 min.
Temperature range in motion -5°C till +70°C
fixed -20°C till +70°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard EN 60332-1-2


Main properties

NoTest itemProperty
1ConstructionListed to the tables
2Conductor resistanceListed to the tables
3Voltage testA.C 3.5kV 5minNo breaken
4Mechanical properties before agingTensile strengthInsulationMin.12.5N/mm²
SheathMin.12.5N/mm²
Elongation at breakInsulationMin.150%
SheathMin.150%
Mechanical properties after agingTensile strengthInsulation

100°C±2°C 7days

Min.±12.5N/mm²

Sheath

100°C±2°C 7days

Min.±12.5N/mm²

Varying valve of tensile strengthInsulation

100°C±2°C 7days

Min.±25%

Sheath

100°C±2°C 7days

Min.±25%

Elongation at breakInsulation

100°C±2°C 7days

Min.±150%

Sheath

100°C±2°C 7days

Min.±150%

Varying valve of tensile strengthInsulation

100°C±2°C 7days

Min.±25%

Sheath

100°C±2°C 7days

Min.±25%

5Flame-retardant propertyComply with GB12666.5-90(CB) and IEC332-3(CB)
6Constant of insulation resistivityMin at 20°C36.7
Ki MΩ.kmMin at 70°C0.037