Add to Cart
Vishay Celtron HCD High Precision Truck Scale Load Cell Load Cell Tensile Tester Load Cell
Alloy steel products
2. Metal welding seal
3. Category: 25K, 50K, 100Klb
4. Comprehensive accuracy: 0.05%
5. Protection level: IP67
6. Truck scale, track scale, barrel metering, batching system
Celtron HCD load cell technical parameters
Standard Capacity | 25K, 50K, 100K lb | ||
Recommended Excitation | 10 V AC/DC | Compensated Temp. Range | -10°C to +40°C |
Maximum Excitation | 15 V AC/DC | Operating Temp. Range | -20°C to +60°C |
Output at Rated Load | 3 mV/V±0.25% | Zero Balance | ±1% |
Combined Error | 0.05% | Input Resistance | 385±5 * |
Non Repeatability | 0.02% | Output Resistance | 350±3 + |
Creep (20 minutes) | 0.03% | Insulation Resistance(50VDC) | >5000 M |
Zero Return (20 minutes) | 0.03% | Deflection at Rated Load | <0.5mm |
Temp. Effect/10°C on Span | 0.015% | Safe Overload | 150% |
Temp. Effect/10°C on Zero | 0.026% | Ultimate Overload | 300% |
*:770 for 100K lb | +:700 for 100K lb |