Add to Cart
1260~1650nm Optical Line Protection Module,RS-232 serial port,LC/UPC
Overview
GZ-OLP-M-LP optical fiber protection module is a main fiber and
standby optical fiber fault automatic light path switching module,
the module monitoring main fiber and standby fiber at the same
time, when the main optical fiber power signal is below the set
value and
standby optical fiber signal is normal, the module automatic
switching optical path to standby optical fiber;When for standby
optical fibe power signal is below the set value and the main
optical fiber signal is normal, the module automatic switching
optical path to the main optical fiber;The module supports RS - 232
serial port communication, can be set up by agreement or query
module information.
Feratures
•Channel low insertion loss and high stability
•Real-time monitoring of the main optical fiber and standby optical
fiber optical power size. •Optical fiber main/standby switch
automatically. •Supports RS-232 serial port communication
Schematic diagram
Specifications
Parameter | Parameter Values |
Model | GZ-OLP-M-LP |
Insertion Loss | ≤1.5 dB |
Wavelength Range | 1260~1650nm |
Optical Power Switching Value | -10dBm,-15dBm,-20dBm,-25dBm,-30dBm,-35dBm (1550nm) |
Accuracy | ±5% |
Lifetime | ≥ 107 |
Fiber Type | 9/125 um |
Connector | LCPC |
Control Mode | RS-232 |
Power Down State | Latching |
Working Power Supply | DC:5V/500mA |
Operating Temperature | 0 ~ +50℃ |
Storage Temperature | -10 ℃ ~ +70 ℃ |
Product Size | (L)104.0×(W)120×(H)28±0.2mm |
Panel description
Connector 1: optical fiber Connector (common port)
Connector 2: optical fiber Connector (main fiber)
Connector 3: optical fiber Connector (standby fiber)
Indicator light 1: When the indicator light is green, the module
works as the main optical fiber; when it is red, the module works
as the spare optical fiber.
Indicator light 2: When the indicator light is green, the main
fiber signal is normal; when it is red, the main fiber signal is
out of order
Indicator light 3: When the indicator light is green, the standby
fiber signal is normal; when it is red, the standby fiber signal is
out of order
SET:The key is used to switch between the main fiber and the
standby fiber
RS-232: Serial communication interface;
Power:Power interface(5V/500mA)
Default Setting
•RS-232:Baud rate:9600; Data bits:8 bit; Stop bit: 1 bit; Parity
bit:NONE; •Optical Power Switching Value: -35dBm
SET:Allows setting
RS-232 pin definition
Pin | Name | Explain |
1 | NC | NC |
2 | RXD | receiving terminal |
3 | TXD | sending end |
4 | NC | NC |
5 | GND | GND |
6 | NC | NC |
7 | NC | NC |
8 | NC | NC |
9 | NC | NC |