CE RoHs SAA ETL 100 VAC IP65 80 Watt LED Flood Light
Slim led flood light 80W 240VAC asymmetric optic 40 4000K
waterproof IP66 5years
Specialty Voltage Lighting
LCD offers specialty voltage options in both Flood and High bay
models. Offering a unique solution for both 180-518V AC with
Meanwell and 12VDC & 18-32V DC applications, the Flood and High
bay Area Light offers the same performance, reliability, optics and
energy efficiency expected from a LCD-CESP fixture. These models
eliminate the need to rewire—simply install Area Lights in existing
circuits saving time and money on retrofit installations.
- Most flexible product offering of 18-32V DC and 180-518V AC models
- DC models for Marine boat, vessel, work site,solar, wind, battery
and generator-powered use
- Outdoor security location certification for weather proof
industrial & harsh environments
- Shock and vibration resistant & IP66/67 rated
- 5-10 year warranty
The FK Series Features
is available in 10W, 30W, 50W, 100W, 150W and 200W options giving
you the general floodlighting ability to illuminate industry &
light commercial areas.
- One box solution with colour select and lumen select
- Bonus bracket for corner mounting
- Anti-fog diffuser with breather in-built cable gland
- Textured tempered glass to minimize glaze, 316 grade stainless
steel screws
- Black Powder coated die-cast Aluminium LM6 Body profile with
excellent heat sink capability
- Hassle-free with pre-wired 1 meter flying lead and angled Trunnion
arm for easy installation
- IP65 Ingress protection IK06 impact resistance
- Operation temperature to max 40°C 25,000 to 50,000 hours L70 B50 5
year warranty
80W FK Floodlight
Product Number | LCD-FK-085 |
Rated Power | 80W |
Rated Voltage | 90-305VAC |
Lumen (lm) | 9600lm |
Power Factor | >95 |
Color Temperature | 3000-6000 K |
CRI (Ra) | >75 |
IP Rating | IP65 |
LED Chip & Type | LUMILEDs SMD3030 |
Driver | Meanwell/philips |
Lifespan | >50,000hr |
Housing Material | Aluminum |
Operating Temperature | -30°C~ 50°C |
Beam Angle | 65°/ 90°/ 120° |
Warranty | 5 years |
Certification | CE -RoHs-SAA-ETL-TUV |
CAUTION
RISK OF PRODUCT DAMAGE
- Never connect luminaires and/or components under load with supply
voltage turned on.
- Do not mount or support these luminaires in a manner that can cut
the outer jacket or damage wire insulation.
- Do not restrict fixture ventilation. Allow for some volume of
airspace around luminaire. Avoid covering luminaire with
insulation, foam or other material that will prevent convection or
conduction cooling.
- Do not exceed luminaire maximum ambient temperature.
- Do not modify the luminaire.
- Only use luminaire in its intended application and location.
- Led products are polarity sensitive. Ensure proper polarity before
installation.
- Electrostatic Discharge (ESD) can damage LED. Personal grounding
equipment must be worn during all installation and servicing of the
luminaire.
- Do not touch individual electrical components as this can cause
ESD, shorten LED life, or impact LED performance.
- Always read the luminaires complete installation instructions prior
to installation for any additional luminaire specifific warnings.
- In the case of HID or Fluorescent luminaires, regular re‐lamping is
required to keep luminaire operating within safe limits
- Do not install damaged product. Handling and installing damaged
products can potentially increase the risks mentioned In case of
damage and/or missing parts upon arrival of the luminaire, please
contact us.
- These instructions do not purport to cover all details or
variations in equipment nor to provide every possible contingency
to meet in connection with instal‐lation, operation or maintenance.
- Please see luminaire specifific Installation and Maintenance
Instruction for additional warnings or any applicable LCD or
regulatory statements. Failure to follow any of these Instructions
could void luminaires warranties.
Luminaire Maintenance
- Regular luminaire maintenance programs are recommended.
- It is recommended to clean the outside of the luminaire and the
refractor/lens.
- Frequency of cleaning will depend on ambient dirt level and minimum
light output which is acceptable to user.
- If clean water is not sufficient for cleaning, use a neutral,
synthetic, not‐scratching and not‐abrasive cleaning substance.
- Never use alkaline and/or acetous cleaning substances.
- Make sure that the cleaning substance is carefully removed by
rinsing with lots of clean water.
- LCD recommends using a cleaning solution that has a PH between 5
and 8.
Product Photos:
Company Profile
LCD-CESP is the leading innovator in Lighting design.
We strive to offer the best service to our customers
Our lighting products are market leaders and have many unique
features.
We offer a minimum of 5 years warranty.
Most of all Customer satisfaction is our priority.
Our R+D team have many years in the lighting Industry and we offer
the following skills to our customers-
Mechanical design
Electronic design
Optic testing
We are sourcing components to the highest specification.
Our manufacturing and assembly processes are to ISO 9001 and ISO
1400 requirements.
We offer customisation and design services.