Add to Cart
vertical type one step granulator fluid bed granulating equipment
Application
vertical type one step granulator fluid bed granulating equipment is mainly used for the operations of mixing, granulating, drying
and coating of granule, "Top Spraying", etc of powder material in
pharmaceutical industry, foodstuff industry, chemical industry,
etc. Such as granule of tablet, granule for quick resolving
drinking, condiment.
vertical type one step granulator fluid bed granulating equipment is manufactured in accordance with JB20014-2004 Fluid-bed
Granulator In Medicine
Principle
The powder granulation in the container (fluidization) appear in
the state of fluidization. It is preheated and mixed with clean and
heated air. At the same time the solution of adhesive solvent is
fogged and sprayed into the container. It makes the some particles
become granulating that contains adhesive. Being of unceasing dry
through hot air, the moisture in the granulation is evaporated and
the adhesive is solidification. The process is carried out
continuously. Finally it forms ideal, uniform and Porous granules.
Features
Flow chart
1. Liquid material tank
2. Feed pump
3. Bottom hopper
4. Air heater
5. Air filter
6. Air valve
7. Suction fan
8. Silencer
9. Lift-up cylinder
10. Container
11. Middle hopper
12. Upper hopper
13. Sight glass
14. Shake cylinder
15. Bag filter
16. Exhaust cylinder
17. Control cabinet
Technical Parameters
Item | specification | ||||||||||||||
Name | Unit | 3 | 5 | 15 | 30 | 45 | 60 | 90 | 120 | 150 | 200 | 300 | 500 | 800-1000 | |
Container Volume | L | 12 | 22 | 45 | 100 | 155 | 220 | 300 | 420 | 550 | 670 | 1000 | 1500 | By client | |
Capacity | kg/batch | 3 | 5 | 15 | 30 | 45 | 60 | 90 | 120 | 150 | 200 | 300 | 500 | ||
Steam | Pressure | Mpa | 0.4-0.6 | ||||||||||||
Consumption | kg/h | 10 | 18 | 35 | 60 | 99 | 120 | 130 | 140 | 161 | 180 | 310 | 400 | ||
Power of fan | kw | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 22 | 30 | 45 | ||
Power of electricity heater | kw | 6 | 9 | ||||||||||||
Noise | dB | Not more than 75dB Separated of fan | |||||||||||||
Compressed air | Pressure | Mpa | 0.6 | ||||||||||||
Consumption | m 3 /min | 0.3 | 0.3 | 0.6 | 0.6 | 0.6 | 0.9 | 0.9 | 0.9 | 0.9 | 1.1 | 1.3 | 1.5 |