Kilns Cooling Steam Power Plant Mine 3000rpm Centrifugal Ventilation Fans

Brand Name:SIMO
Certification:CE, ISO9001:2008,TUV
Model Number:SIMO Blower 5-06
Minimum Order Quantity:1 Set
Delivery Time:15-35 Days
Payment Terms:T/T, L/C, Payment Term Is Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Xinxiang Henan China
Address: No.343, SIMO Road, FengQuan District, XinXiang City, HeNan Province, China
Supplier`s last login times: within 31 hours
Product Details Company Profile
Product Details

Kilns Cooling Steam Power Plant Mine Ventilation Centrifugal Blower Fan


Detail introduction


The 5-06 series fan can be used in the feeding system of 2-670t/h steam boiler in thermal power plants, it can also meet the requirements of the high-pressure head performance parameters of the fluidized bed furnace.

This series of fans can also be used for dust removal, mine ventilation and general ventilation systems. The blower delivers air, and the induced draft fan delivers flue gas or gas containing foreign particles.

It can be used for more than four years when the concentration of impurities is less than 200 mg/m3.

If it contains a lot of impurities, it also can be used, but it will shorten the service life.

The maximum operating temperature of the induced draft fan must not exceed 250°C.

The performance of the fan is expressed by parameters such as fan flow, full pressure, spindle speed, shaft power and efficiency.


Product features


1. Impeller:

12 pieces of backward aerofoil blades are welded between the Arc cone front plate and the flat shaped rear plate. Because of the use of airfoil blades, the fan is guaranteed to have high efficiency, low noise and high strength. The impeller is corrected by static and dynamic balance, so the operation is stable. Forced draught fan and induced draught fan of the same machine number have same impeller structure.


2. Casing:

The casing is a volute welded by ordinary steel plates.

The casing of a single suction fan is made in three different forms: The No. 8 to 12 casing is made into an integral structure and cannot be disassembled; The No. 14 to 16 casing is made into a two open structure; The No. 18~29.5 casing is made into a three open structure.

The induced draft fan and the volute plate are appropriately thickened to prevent wear.


3. Inlet:

The converging and streamlined air inlet is made into a unitary structure and bolted to the inlet side of the fan.


4. Adjustment door:

A device for regulating the flow of the fan, axially mounted in front of the air inlet. The adjustment range is from 0° (full open) to 90°(fully closed).


5. Transmission parts:

The main shaft of the transmission part is made of high-quality steel, and the 5-51 series of fans are all made of roller bearings.

The bearing housing is available in two forms: No. 8 ~ 16 uses a whole cylindrical bearing housing; No18 ~ 29.5 uses two independent pillow bearing boxes.

The bearing housing is equipped with a thermometer and an oil level indicator (only the induced draft fan). The lubricating oil uses 46# mechanical oil, and the oil quantity is implemented according to the oil level mark. When the No8-16 integral cylindrical bearing housing uses dry oil, the oil retaining plate should be added to the ball side of the bearing housing, and the fixing grooves communicate with each other. The induced draft fan is equipped with a water cooling device, so a water supply pipe must be installed. Water consumption varies with temperature, and is generally considered to be 0.5 to 1 m3/h.


Technical specifications


Series no.5-06 seriesFeature selection
Normalanti-corrosionwear-resistingHigh temperatureanti-explosionRemarks
PerformanceImpeller diameter400-2500mm
Rotation speed≤3000rpm
Pressure range1567-5764Pa
Flow range2470-377586㎥/h
StructureBlade typeBackward, Straight, Aerofoil type
Impeller supportSWSI(Single Width, Single Inlet), DWDI(Double Width, Double Inlet), Overhung type
Lubrication methodOil bath lubrication, grease lubrication, lubrication oil stationCan be specified
Cooling methodAir cooling, Water cooling, Oil coolingCan be specified
Driven modeDirect driven, Coupling driven, Belt drivenCan be specified
Gas compositionGas temperatureNormalCustomer requestCustomer request≥250℃Customer request
gas characteristicClean gasCorrosive gasParticulate dustHigh temperature gasFlammable gas, explosive gas
System configurationMotor brandChinese famous brand, ABB, Siemens, WEG etcCan be specified
ImpellerHigh quality carbon steelFRP, Stainless steel, Rubber LiningWear-resistant layer or wear-resistant liner, ceramic patchHigh temperature high quality alloy steelFRP, Aluminum alloyCan be specified
Air inlet coneHigh quality carbon steelFRP, Stainless steel, Rubber LiningHigh quality carbon steelHigh quality carbon steelHigh quality carbon steelCan be specified
CasingHigh quality carbon steelFRP, Stainless steel, Rubber LiningHigh quality carbon steelHigh quality carbon steelHigh quality carbon steelCan be specified
Air damperHigh quality carbon steelFRP, Stainless steel, Rubber LiningHigh quality carbon steelHigh quality carbon steelHigh quality carbon steelCan be specified
Main shaftHigh strength carbon steel, Alloy structural steelCan be specified
BearingZWZ, SKF, FAG, NSKCan be specified
Bearing housingCast iron
Foundation boltsGB799-1988
Option partsSystem base frame, Protective screening, Silencer, Inlet & Outlet flexible connections, Inlet & Outlet counter flange, Air damper, Electric actuator, Shock absorber, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibration sensor, Soft starter, Inverter, Special Electrical Motor, System monitoring Instrument.

FAQ


1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.


2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.


3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.


China Kilns Cooling Steam Power Plant Mine 3000rpm Centrifugal Ventilation Fans supplier

Kilns Cooling Steam Power Plant Mine 3000rpm Centrifugal Ventilation Fans