Portable Medical Ventilator Machine , Ventilator Oxygen Machine For First Aid Room

Brand Name:OEM
Certification:CE / FDA
Minimum Order Quantity:Negotiable
Delivery Time:3 working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Product name:Portable mechanical ambulance ventilator
Contact Now

Add to Cart

Active Member
Location: Yiyang Hunan China
Address: Building 31, Taojiang Economic Development Zone, Taojiang County, Yiyang City, Hunan Province, China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Portable Medical Ventilator Machine , Ventilator Oxygen Machine For First Aid Room


Technical Specifications:

Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa

safety valve <12.5 kPa

Respiratory Rate 1~99 bpm

gas concentration output 21% ~ 100% adjustable

Maximum Minute ventilation ≥18L / min, permissible deviation: ±20 %

Breathing Mode A/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV, PEEP,SIGN,VCV, SPONT, MANUAL

Ventilator compliance ≤30 Ml/kPa

PEEP: 0~1.0KPa

Ptr: ,-1.0~1.0 kPa

IMV frequency: 1 ~ 12 times/min, permissible deviation: ±15%.

I/E Ratio: 4:1~1:4

Tidal Volume range 0~2000ml

Inspiratory Plateau: 0~1s

Maximum Safety Pressure ≤ 6.0kPa

Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point and the permissible error is -10% or 15%.

Pressure limit range: 1.0~ 6.0kPa

Airway pressure alarm: Audible and visual and with yellow and red color indicating upper alarm: 0.9 kPa ~ 5.4 kPa

lower: 0.5kPa

Ventilation Volume alarm: ≥ 18L/ MIN

Power Supply Alarm "Ac/dc power supply are after failing to send out alarm immediately

Alarm Time: keep >120s"

The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.


Ambient temperature10 ~ 40oC
Relative humidityno higher than 80 %
Atmospheric pressure860 hPa ~ 1060 hPa
Power requirement100-120 Vac, 50/60 Hz;
Air source requirementMedical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.
Attentionthe AC power supply used for the anesthesia machine must be well grounded.
Attentionthe anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment
Part IISpecial Requirements for Safety and Basic Performance of Anesthesia System.
China Portable Medical Ventilator Machine , Ventilator Oxygen Machine For First Aid Room supplier

Portable Medical Ventilator Machine , Ventilator Oxygen Machine For First Aid Room