Lcd Display Respirator Mobile Breathing Machine Used In Hospitals Trolley Type For Icu Room

Certification:CE FDA
Payment Terms:T/T
Price:Negotiation
Color:White,Orange red yellow blue grey etc.,Grey
Logo:as you required
Li-battery:2200mAH
Contact Now

Add to Cart

Active Member
Location: Foshan Guangdong China
Address: Fuze Building, Xingye Road, Nanhai District, Foshan City, Guangdong Province,China
Supplier`s last login times: within 40 hours
Product Details Company Profile
Product Details

LCD Display Respirator Mobile Ventilator Machine Trolley type


Introduction


entilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.


Parameters


TECHNIQUES SPECIFICATIONS
Physical specifications
DisplayLED Display
Mode:pneumatically powered and electrically controlled system
Trolley:Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement:Medical oxygen with a pressure ranging from 280~600kpa
safety valve<12.5 kPa
Respiratory Rate6~60 times/ min
Oxygen concentration output<50%
minute volume≥18L
modes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH
PEEP:0.1 ~ 1.0 kPa
Ptr:-4 ~ 10 hPa
IMV frequency:1~12 bpm
I/E Ratio:1:1.5; 1:2.0; 1:2.5; 1:3.0
Tidal VolumeNot less than 50~ 1200ml
Inspiratory Plateau:0~1s
Maximum Safety Pressure≤ 6.0kPa
Sigh:one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range:0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.9 kPa ~ 5.4 kPa; Upper: 0.5 kPa
±0.2 kPa
Ventilation Volume alarm:≥ 18L/ MIN
Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature:10 ~ 40oC
Relative humidity:no higher than 80 %
Atmospheric pressure:860 hPa ~ 1060 hPa
Power requirement:100-120 Vac, 50/60 Hz;
Attention: the AC power supply used for the ICU ventilator must be well grounded.
Storage
Ambient temperature:-15oC ~ +50oC
Relative humidity:no higher than 95 %
Atmospheric pressure:86 kPa ~ 106 kPa.
It should be stored in a room without corrosive gas and well ventilated
Package
packaging boxcomply with the requirement of GB/T 15464
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.
Tidal Volume Alarm
China Lcd Display Respirator Mobile Breathing Machine Used In Hospitals Trolley Type For Icu Room supplier

Lcd Display Respirator Mobile Breathing Machine Used In Hospitals Trolley Type For Icu Room

Inquiry Cart 0