Add to Cart
The Anti Igniting Test Machine is an analog cigarettes and matches
as flame ignition source for resistance to ignition of upholstered
furniture conduct test methods and evaluation.
This section applies to public places with mattresses, sofas and
other upholstered furniture resistance to ignition test and
evaluation, furniture Soft package resistance to ignition.
ISO 8191-1~2:1988:ISO 8191-1:1987 Furniture — Assessment of the ignitability of upholstered furniture
— Part 1: Ignition source: smouldering cigarette;
— Part 2: Ignition source: match-flame equivalent
EN 597-1~2:Fire test for mattresses and upholstered bed bases - Products Scope:This standard lays down a test method to assess the ignitability of mattress, upholstered bed bases or mattress pads when subjected to a smouldering ignition cigarette.
EN 597-2: Fire test for mattresses and upholstered bed bases - Products Scope: This standard lays down a test method to assess the ignitability of mattress, upholstered bed bases or mattress pads when subjected to a gas flame equivalent to a match flame
Part of the test and the sample box seat
1.The size of combustion box: length 3000mm, width 3000mm, height
2700mm;
2.There is fire resistant cabinet Caigangyanmian plate made;
3.The side of the box and opened a vent with fan; external exhaust
pipes;
4.Openeda sealed box side windows; beautiful, easy to observe the
experiment outside;
5. Increase the door, easy access to mattress and sofa;
6. The box is equipped with explosion-proof lampsprovidelighting
inside;
7. The specimen bearing groove is made from stainless steel plate,
corrosion-resistant; dimensions of 2200mm X 2000mm X100mm;
8. Bearing grooves may collect water used forfire fightingand
combustion residue; andthe design of the drain; chamber floor to
avoid contamination;
9.Stainless steel frame, for supporting the bearing groove; height
30mm;
1. Timing range: 0-999S, respectively, display and recording
continued burning or smoldering time, fabric cracking time, the
specimen is off time,
2. Test distance igniter: 20-80 adjustable, with automatic movement
and evacuation ignition mechanism.
3. The flow measurement range: 10 ~ 100m1 / min
4. Ignition source system: Stainless steel burner tube, an inner
diameter (8 ± 0.1mm) inner diameter (6.5 ± 0.1mm) in length (200 ±
5mm) prepare two sets
5. Hose: Length should be (2.5 ~ 3mm) inside diameter of (7 ± 1mm)
and stainless steel pipe connected to the combustion5. Flow control
system: Including a flow meter, trim valve, switch valve and
regulator.
6. Flow (45 ± 2) m1 / min need to provide the name of the output
pressure of the system for 2.8kpa
7. Filter-tipped cigarette of, or remove the filter tip cigarettes
cylinder and interface package, and meet the following
requirements:
8. Observation window: A glass large observation window, surrounded
by SUS304 stainless steel edging
9. Computer control system (test time, number of trials, extended
burn time can be set in the computer and record having high
intelligence, guided menu operation, simple and intuitive features,
making test results more accurate.
10. Automatic ignition function (for the high-voltage electronic
electrical fire).
11. PC using configuration software can automatically generate a
temperature curve and the report output data acquisition and print
test results