

Add to Cart
I. Introduction:
1. The Calorific Value Testing Machine is designed and made
according to GB/T213-2008 Method for the determination of the
calorific value of coal,
GB/T384 Method for the determination of the heat value of petroleum
products and Calibration and Inspection Regulation of People’s
Republic of China JJG672-2001 Oxygen Bomb Calorimeter.
2. This Calorific Value Testing Machine is suitable for the
determination of water free oil products (gasoline, jet fuel,
diesel oil and fuel oil, etc.) and combustible material such as
coal, coke, paraffin wax content determination of calorific value.
3. This calorific value tester is a high grade instrument with the advantages of automatic, efficient, safe, high precision, fast test speed and easy to use.
II.Features:
1) The Calorific Value Testing Machine uses a single-chip control
technology, color LCD display, high-precision temperature sensor
and high-performance A / D conversion device, consisting of a high
degree of automation, screen effect is good, easy to use,
convenient intelligent data compilation instrument.
2) The Calorific Value Testing Machine is fully automated in the
testing process, after the sample in place, correct input various
parameters automatically without manual intervention to complete
each test process; you can print measurement data directly on the
A4-format printer configuration after the end of the trial.
3) This Calorific Value Testing Machine adopts the self sealing
type oxygen bomb, all the structure is made of stainless steel, and
the strength is enough to withstand the pressure test of 20MPa at
room temperature.
4) The inner tube of the heat value tester is made by stainless
steel sheet, section of pears, put the barrel of water was 3000
grams, water cylinder with electric blender, to ensure that the
inner tube water bath temperature uniformity.
5) The automatic oxygen bomb calorimeter of the external water
jacket is a double container and experiment when filled with water,
through the water jacket mixer to cylinder in uniform temperature,
formed to meet the test requirements of the constant temperature
environment.
III.Specifications:
Heat capacity | (14000 ~ 15000)J/K |
Temperature resolution | 0.001 K |
Thermal error | ≤60J/g |
Temperature measurement range | 10 ℃~35 ℃ |
Repeatability error | ≤0.2% (Grade C) |
Pressure endured by Oxygen bomb | 20 MPa |
Ambient temperature | 15 ℃~28 ℃ (room temperature), The temperature fluctuation during each test should be not more than 1 ℃ |
Storage Temperature data | 31 |
Ambient humidity | less than 85% |
Power supply | AC(220±5%)V,50Hz |
Total power consumption | less than 150W |
Dimensions | 600 mm × 460 mm × 430 mm (length × width × height) |
Note: If the test sample is pulverized coal samples, in order to
obtain better test results, we recommend separately of the company's private press cake machine. |