12kv 11kv Vacuum Load Break Switch / Electrical Load Break Disconnect

Brand Name:XK
Certification:ISO9001 / GB / IEC
Model Number:FN12
Minimum Order Quantity:1 Piece/Pieces
Place of Origin:china
Supply Ability:100 Piece/Pieces per Month
Contact Now

Add to Cart

Active Member
Address: No.318 Shengli Road, Xixi Village, Huheng Industrial Zone, Yueqing City, Zhejiang Province.
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

12kv vacuum load breaker switch electrical load break switch vacuum load switch

Hot sale 12KV safety indoor AC high voltage load breaker switch

Product Description


Zhejiang Xinkou Power Equipment Co.,Ltd, is a high-tech enterprise specializing in developping, design, manufacture, sales, import and export of low voltage and high voltage electrical products.

Company main products: indoor and outdoor high voltage vacuum circuit breaker, load break switches, disconnecting switches, drop out fuse cutour, lightning arrester, etc. All products comply with the requirements of GB, IEC, ANSI and other international standard.

ltemUnitData
Rated voltageKVFN12-12D/630FN12-12(R)D/125
Rated frequencyHZ12
Rated currentA50
1min power frequency withstand voltageKV42 to ground and phases fracture 48
Lightning impulse withstand voltageKV75 to ground and phases fracture 85
Rated thermal stable currentKA
630
100
Rated dynamic stable currentKA
50
Rated switching current(peak)KA
50
50
Rated short-circuit current(expected)KV
31.5
Maximum breaking current thresholdHZFuse characteratic curve accorting
Minimum breaking currentAFuse characteratic curve accorting
Rated transfer currentKV
50
1.5
Maximum breaking currentKV1.8
Breaking OFF-load transformer capacityKV/A1250
Rated cable charging currentA10
Rated active load current breaking timesTimes10000
Opening time when striker strikesS<0.06
Earth switch thermal current switchKA20(2S)
Thermal stable current of earth switchKA5050
Motor operating power supply voltageVAC/DC 110/220

12kv vacuum load breaker switch electrical load break switch vacuum load switch

ltemUnitData
FN12-10D/630FN12-10(R)D/125
The total traveling distance of moving contactmm200+8-2
Phase center distance (Before energy storage)mm210±15
Moving contact overtravel distancemm40±2
Auxiliary contact opening distancemm>150
Opening/Closing time difference among three phasems<3
Opening speedm/s>2.8>2.8
Closing speedm/s>3.8
Distance between metal flexible door and torchmm>125
Fracture distance of earth switchmm>150
Main circuit resistanceΩ<120<300
Maximum operating torqueNM>160