Hrc 33kv Drop Out Fuse / 200a 100a Cut Out Fuse High Breaking Capacity

Brand Name:XK
Certification:ISO9001 / GB / IEC
Model Number:33KV DOFC-0855
Minimum Order Quantity:99 - 299 Pieces
Place of Origin:Zhejiang, China
Supply Ability:3000 Piece/Pieces per Month
Contact Now

Add to Cart

Active Member
Address: No.318 Shengli Road, Xixi Village, Huheng Industrial Zone, Yueqing City, Zhejiang Province.
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

High quality H.V. DOFC series safety high-voltage fuse

Product Description

TypeUnitPD-12/100PD-12/200
Rated voltageKV10—1510—15
Rated currentA100200
Breaking currentA1000012000
lmpulse voltageKV110110
Power frequency withstand volatageKV4242
Creepage distanceMM250250
WeightKG77
DimensionsCM38.5×34.5×10.538.5×34.5×10.5

33 kv drop out fuse high voltage drop-out fuse high voltage hrc fuse

TypeUnitPD-15PD-15
Rated voltageKV15-2715-27
Rated currentA100200
Breaking currentA1000012000
lmpulse voltageKV125125
Power frequency withstand volatageKV4545
Creepage distanceMM355355
WeightKG8.88.8
DimensionsCM51.5×34×1251.5×34×12

33 kv drop out fuse high voltage drop-out fuse high voltage hrc fuse

TypeUnitPD-24PD-24
Rated voltageKV24-2724-27
Rated currentA100200
Breaking currentA800010000
lmpulse voltageKV150150
Power frequency withstand volatageKV6565
Creepage distanceMM505505
WeightKG1212

33 kv drop out fuse high voltage drop-out fuse high voltage hrc fuse

TypeUnitPD-11PD-11
Rated voltageKV2424
Rated currentA100200
Breaking currentA1000012000
lmpulse voltageKV150150
Power frequency withstand volatageKV6565
Creepage distanceMM540540
WeightKG4.54.5
DimensionsCM51×34×11.551×34×11.5

33 kv drop out fuse high voltage drop-out fuse high voltage hrc fuse

TypeUnitPD-12PD-12
Rated voltageKV1515
Rated currentA100200
Breaking currentA1000012000
lmpulse voltageKV110110
Power frequency withstand volatageKV4545
Creepage distanceMM245245
WeightKG3.83.8
DimensionsCM45×34×11.545×34×11.5

33 kv drop out fuse high voltage drop-out fuse high voltage hrc fuse

TypeUnitPD-13PD-13
Rated voltageKV3333
Rated currentA100200
Breaking currentA60008000
lmpulse voltageKV170170
Power frequency withstand volatageKV7070
Creepage distanceMM660660
WeightKG1515
DimensionsCM56×38×11.556×38×14.5

33 kv drop out fuse high voltage drop-out fuse high voltage hrc fuse

TypeUnitPD-36/100PD-36/200
Rated voltageKV3636
Rated currentA100200
Breaking currentA1000012000
lmpulse voltageKV170170
Power frequency withstand volatageKV7070
Creepage distanceMM720720
WeightKG55
DimensionsCM61×34×11.561×34×11.5

33 kv drop out fuse high voltage drop-out fuse high voltage hrc fuse

What are its components?
A cutout consists of three major components:
Body:
The frame which supports the fuse tub/blade and is mounted to the crossarm or bracket. The insulator body on this frame can be either polymer or porcelain material. The live connector parts are also mounted to the ends of this frame.
Fuse Holder:
Known as the fuse tube or “door” that contains the fuse link. This piece acts as a simple switch. When the fuse operates, the fuse holder will drop open disengaging the switch from the line. This ensures any downstream circuits are electrically isolated.
Fuse Link:
Also known as an element, is the replaceable portion of the product that extinguishes due to higher than normal current transfers.

China Hrc	33kv Drop Out Fuse / 200a 100a Cut Out Fuse High Breaking Capacity supplier

Hrc 33kv Drop Out Fuse / 200a 100a Cut Out Fuse High Breaking Capacity

Inquiry Cart 0