1. Introduction

LWGYML series turbine flow meter is a new generation kind of flow meter that absorbs the advanced technologies of flow meter at home and abroad. It has been optimized and designed to have so many characteristics, such as simple structure, light weight, high precision, good repeatability,easy installation and usage.


It is widely used in the sealed pipelines which doesn’t have corrosion function on SS 1Cr18Ni9Ti, 2Cr13, corundum Al2O3 and cemented carbide and have no fiber, particle and so on. The liquid should be less than 5*10-6m2/s with viscosity under working temperature, if the viscosity of the liquid is more than 5*10-6m2/s, then the flow meter can be used after calibration. If it is equipped with other display devices with special functions, it can also do quantity control, excessive alarm and so on. It is really perfect in flow measurement and energy

conservation.


2. Features

  • High accuracy, usually reach ±1%R,±0.5%R,or even reach ±0.2%R for high-precision type.
  • Good repeatability, it can reach 0.05%-0.2% in short term, if regular calibration or online calibration can get an extremely high accuracy, so it is preferred in foreign trade.
  • Pulse signal output, it is suitable for totalizer measurement and computer connection, no zero drift,strong capacity of resisting disturbance.
  • High frequency signal(3-4KHz), strong signal resolution.
  • Wide range, middle and big diameter can reach 1:20, and small diameter can reach 1:10.
  • Compact structure, easy installation and maintenance.

3. Application

Turbine flowmeter is widely used in the following measurement objects: petroleum, organic liquid, inorganic liquid, liquefied gas, natural gas, gas and cryogenic fluid. It is widely used in foreign LPG, refined oil and light crude oil transfer and gathering stations, as well as in the initial and terminal stations of large crude oil pipelines for trade settlement. In Europe and the United States, turbine flowmeter is second only to orifice flowmeter for natural gas metering. Holland alone has adopted more than 2600 gas turbine flowmeters with various sizes and pressures ranging from 0.8MPa to 6.5MPa on natural gas pipelines. They have become excellent natural gas flow meters. Although the excellent metering characteristics of turbine flowmeter are favored by people, it gives the impression that it is composed of moving parts with short service life, which makes it hesitant to select it. After unremitting efforts, it should be said that the situation has been greatly improved. As the most common flowmeter, turbine flowmeter has been developed into a large scale of multi variety, full series and multi specification batch production.


Turbine flowmeter is widely used in some special departments, such as scientific research and experiment department, national defense science and technology department and measurement department. The use of these fields just avoids its weakness (not suitable for long-term continuous use), and gives full play to its characteristics (high precision, good repeatability, and can be used in high pressure, high temperature, low temperature and micro flow conditions). In these fields, most of them are designed according to the special requirements of the tested object. They are special instruments and do not carry out mass production.


4. Specifications

Pipeline Diameter(mm)
and
Connection
4,6,10,15,20,25,32,40
Thread Connection
(15,20,25,32,40) 50,65,80,100,125,150,200
Flange Connection
Accuracy±1%R,±0.5%R,±0.2%R(Special Order)
Turn Down Ratio10:1; 15:1; 20:1
Material304SS,316(L)SS, etc
Medium Temperature-20℃~+110℃
Environmental ConditionsTemperature: -10℃~+55℃
Relative humidity: 5%~90%
Atmospheric pressure: 86~106KPa
Power supplySensor:+12VDC,+24VDC(Option)
Transmitter:+24VDC
Local Display:3.2V Lithium Battery
Output SignalSensor:Pulse Frequency Signal(Low level≤0.8V, High level≥8V)
Transmitter:Two Wired 4-20mA Current Signal
Signal CableSTVPV 3x0.3(Three Wired),2x0.3(Two Wired)
Signal Cable ConnectionHouseman Connector(Standard Type)
Inner Thread M20x1.5(Explosion Type)
Transmission Distance≤1000m
Explosion ProofNone(Standard Type)
EXdIIBT6(Explosion Proof)
Protection ClassIP65

5. Flow Range & Work Pressure

Pipeline DiameterNormal Flow Range
(m³/h)
Extended Flow Range
(m³/h)
Normal Pressure
(MPa)
Pressure Rate(MPa)
(Flange Connection)
DN40.04~0.250.04~0.406.312,16,25
DN60.10~0.600.06~0.606.312,16,25
DN100.20~1.200.15~1.506.312,16,25
DN150.60~6.000.40~8.006.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN200.80~8.000.45~9.006.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN251.00~10.000.50~10.006.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN321.50~15.000.80~15.006.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN402.00~20.001.00~20.006.3,2.5
(Flange Connection)
4.0,6.3,12,16,25
DN504.00~40.002.00~~40.002.54.0,6.3,12,16,25
DN657.00~70.004.00~70.002.54.0,6.3,12,16,25
DN8010.00~100.005.00~100.002.54.0,6.3,12,16,25
DN10020.00~200.0010.00~200.001.64.0,6.3,12,16,25
DN12525.00~250.0013.00~250.001.62.5,4.0,6.3,12,16
DN15030.00~300.0015.00~300.001.62.5,4.0,6.3,12,16
DN20080.00~800.0040.00~800.001.62.5,4.0,6.3,12,16

6. Installation Dimension

According to the diameter, choose thread or flange connection to install the senor. As to installation method, please check Pic4, Pic5, Pic6.


Pic4 LWGYML-4~10 Structure & Installation Dimension Diagram

Pic5 LWGYML-15~40 Structure & Installation Dimension Diagram

Pic6 LWGYML-50~200 Structure & Installation Dimension Diagram

Pipeline DiameterLThread ConnectionFlange Connection
(mm)GD
(mm)
d
(mm)
n
DN4295G1/2
DN6330G1/2
DN10450G1/2
DN1575G1θ65θ144
DN2080G1θ75θ144
DN25100G1-1/4θ85θ144
DN32120G2θ100θ144
DN40140G2θ110θ184
DN50150θ125θ184
DN65170θ145θ184
DN80200θ160θ188
DN100220θ180θ188
DN125250θ210θ258
DN150300θ250θ258
DN200360θ295θ2512

7. Configuration

LWGYML Series Turbine Flow Meter Configuration
ModelLWGYML
Pipe Material44mm
66mm
1010mm
......
200200mm
Model DescriptionNNo Display,12VDC Power Supply,Pulse Output, High Level≥8V Low Level≤0.8V
ANo Display,4-20mA 2 Wired Current Output
BLocal Display,Battery Operated
CLocal Display,4-20mA 2 Wired Current Output
C1Local Display,RS485 Output
C2Local Display, HART Output
Accuracy050.5 Grade
101.0 Grade
Turbine TypeWExtended Ratio
SStandard Ratio
MaterialSSS 304
ISS 316(L)
Explosion ProofNNone
EExplosion Type(ExmIICT6 or ExdIIBT6)
Pressure RateNNormal Pressure
HHigh Pressure
Connection TypeTThread Connection
FFlange Connection
FilterNNone
FWith Filter
China 4-20mA Digital Turbine Type Flow Meter DN80  Compact Structure Easy Installation supplier

4-20mA Digital Turbine Type Flow Meter DN80 Compact Structure Easy Installation

Inquiry Cart 0