Add to Cart
Fix Mounting Clamp On Ultrasonic Flow Meter
I. Introduction
ML-6100S is a wall-mounted clamped ultrasonic Flowmeter using jet lag technology. The transmission is designed with FPGA chip and low voltage broadband pulse.Two can provide clamping sensor and plug-in sensor.
The ML-6100S has a 240x128 backlit LCD,4 line menu display, and a clear, user-friendly menu selection makes the Flowmeter easier and easier to use every day, a monthly-annual accumulator.
The parallel operation of positive, negative and net flow accumulators has the capacity of scale factor (span) and BTU.The pulse output and frequency output of the accumulator are transmitted through the open circuit of the relay and the collector.
II. Configuration
Model | Transmitter |
ML-6100S | Wall-mounted Type |
Velocity Range:±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s) | |
Accuracy :±1% of the measure value | |
Repeatability:0.2% of the measure value | |
Display:240*128 back lit LCD | |
Power Supply: 10~36VDC/AC90~245V | |
Transmitter Enclosure: IP65, ABS (Temperature: -20℃~50℃) | |
Output: OCT pulse output 0-10KHz, Relay output, 4-20mA for option | |
Communication: RS232,RS485 | |
Code | Output |
1 | OCT,Relay,RS232/RS485,4-20mA |
2 | OCT,Relay,RS232/RS485,4-20mA, RTD |
Code | Transducer |
TT01 | Clamp-on, IP68. Operating temperature:-40 ℉ ~ +176 ℉(-40℃ ~ +80 ℃) |
TT03 | Clamp-on, IP68. Operating temperature:-40 ℉ ~ +266℉(-40℃ ~ +130 ℃) |
TT05 | Insertion, IP68. Operating temperature:-40 ℉ ~ +266 ℉(-40℃ ~ +130 ℃) |
Code | Transducer Cable Length |
030 | Standard length 30ft (9m) |
XXX | Max length to 1000ft (300m) |
Code | Temperature Transducer |
PT1000 | PT1000 temperature transducer+RTD module(option) |
Code | Data Logger |
SD | SD card(8G)+ SD card module(option) |
Standard model: ML-6100S-1-TT01-030
Description: Standard clamp-on type ultrasonic flow meter, OCT, Relay,
RS485, 4-20mA, 30ft cable with TT01 transducers
IV. Working Principle
External clamp type or pipe section type ultrasonic flow meter is
an instrument that measures liquid
flow in a circular pipe on the principle of "velocity difference method". It adopts advanced multi-pulse
technology, signal digital processing technology and error correction technology, so that the flow meter
can more adapt to the environment of the industrial site, measurement more convenient, economical
and accurate. The products reach the advanced level at home and abroad, and can be widely used in
petroleum, chemical industry, metallurgy, electric power, water supply and drainage and other fields.