200A RSBTT III Transformer Test Bench For Laboratory Or Workshop

Brand Name:RISING
Certification:ISO CE
Model Number:RSBTT III
Minimum Order Quantity:1 Set
Delivery Time:20 working days
Payment Terms:T/T, Western Union, MoneyGram,L/C, D/A, D/P,
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: 1st Floor, Block B, Innovation Park, Changzui Science and Technology Park, Sixth High-tech Road, Jiangxia District, Wuhan City, Hubei Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Automatic Comprehensive 22kV Capacity 2000kVA Transformer Routine Testing Equipment for Laboratory or Workshop

Product Description

1.The experimental subject for the equipment that Party A purchased from Party B meet the following requirements:

■ 35kV ordinary power transformers and special transformers, capacity 20000kVA and below;


2 The experimental subject for the equipment that Party A purchased from Party B must meet the following requirements of voltage classes:

The impedance of the tested transformer is less than 8%, the voltage class is:

■ HV side 35kV, etc.

■ 0.4kV~10kV.LV side:0.4kV~10kV.


3. The experimental subject for the equipment that Party A purchased from Party B meet the following requirements of tested capacity:

HV side voltage level 22kV capacity 2000kVA and below.


4. The experimental subject for the equipment that Party A purchased from Party B must meet the following test requirements:

4.1 Routine testing

■ Transformer no-load current percentage and no-load loss testing;

■ Transformer short-circuit impedance percentage and load loss testing;

■ Transformer power frequency withstand voltage testing;

■ Transformer frequency doubling induced withstand voltage testing;


5 Based on the analysis of experimental ability, the experimental subject for the equipment that Party A purchased from Party B meet the following test ability:

5.1 No-load and load loss test ability

■ For the voltage level of 0.4kV/33kV distribution transformer, it’s ok to use the direct low-voltage circuit testing for no-load and load loss.

■ In conclusion, High voltage current transformer of the variable ratio gear selection (Rated working voltage:3KV): 200/1,100/1,50/1,30/1,20/1,10/1,5/1,1A/1A, total:8 speed, precision grade:0.05%; voltage transformer of the variable ratio gear selection: 3kV/100V,2kV/100V,1KV/100V,0.5KV/100V,total:4 speed, precision grade:0.05%.


Feature/Function
Test ability:
1)Can meet the capacity of 63000KvA, 110Kv and below the oil-immersed transformer (including S9 S11 S13 and amorphous alloy transformer);
2) It can meet the capacity of 31500KvA, 35Kv and below dry-type transformers;
3) Mine explosion-proof transformers that can meet capacity of 6300KvA, 10Kv and below;

4) Special transformer (need to inform detailed capacity and voltage level when ordering).


Test item:

1) Transformer winding resistance test

2) Transformer voltage ratio measurement and connection group number test

3) Transformer no-load current (%) and no-load loss test

4) Transformer short circuit impedance (%) and load loss test

5) Transformer power frequency applied pressure test

6) Transformer induced withstand voltage test


Extensible test project:

1) Transformer partial discharge test

2) No-load harmonic test (0-31th harmonic)

3) Withstand voltage test of transformer oil (0-80Kv)

4) Transformer temperature rise test (can automatically draw temperature rise curve)

5) Insulation resistance test (absorption ratio and polarization index)

6) Transformer anti-interference dielectric loss test

7) Lightning impact test.


Performance indicators:

1. Tested transformer parameters

1.1 Transformer capacity under test (to meet temperature rise test condition, dry type transformer)

10kV level ≤2500KVA

35kV level ≤6300kVA

1.2 Tested transformer voltage level below 35kV on primary side


2. Accuracy

2.1 Voltage Range 0-22kV

2.2 Current Range 0-400A

2.3 Minimum voltage resolution 0.001V* PT ratio

2.4 Minimum current resolution 0.0001A*CT ratio

2.5 Power Minimum Resolution 0.1W*PT Ratio*CT Ratio

2.6 Ambient temperature -10~45°C

2.7 Using Relative Humidity 85%

China 200A RSBTT III Transformer Test Bench For Laboratory Or Workshop supplier

200A RSBTT III Transformer Test Bench For Laboratory Or Workshop

Inquiry Cart 0