

Add to Cart
Indoor Escalator with Vvvf Control Safety Escalator with 30 Degree 1000mm Step Width
Escalators efficiently move large numbers of people with minimum waiting time. However, they operate constantly regardless of the number of passengers they carry. Therefore, even a small decrease in energy consumption produces substantial savings. We have made a number of improvements to the drive mechanism in its easy-to-maintain top machine room, which has been proven superior over many years of experience. An approximate 25% reduction in energy consumption has been achieved by enhancing drive transmission efficiency and reducing friction.
Motor capacity(KW) | Traveling height(ladder width) 1000 | Traveling height(ladder width) 800 | Traveling height(ladder width) 600 | ||||
1000~3300 | 5.5 | 1000~3500 | 5.5 | 1000~3700 | 5.5 | ||
3400~4500 | 7.5 | 3600~4700 | 7.5 | 3800~4900 | 7.5 | ||
4600~4900 | 8 | 4800~5100 | 8 | 5000~5200 | 8 | ||
5000~5900 | 11 | 5200~5900 | 11 | 5300~5900 | 11 | ||
1000 | 1000 | 1158 | 1238 | 1600 | 1660 | 2310 | |
800 | 800 | 968 | 1038 | 1400 | 1460 | 2110 | |
600 | 600 | 758 | 838 | 1200 | 1260 | 1910 | |
Step width | A | B | C | D | E | F | |
Model | Traveling height(mm) | Net Weight KN | capacity | Transporation demension | |||
R1 KN | R2 KN | h | I | ||||
FHE(600)-30 (3600person/h) Speed:0.5m/s | 3000 | 57 | 46 | 41 | 2750 | 10900 | |
3500 | 60 | 49 | 44 | 2780 | 11890 | ||
4000 | 64 | 52 | 47 | 2810 | 12880 | ||
4500 | 66 | 56 | 50 | 2830 | 13870 | ||
5000 | 71 | 59 | 53 | 2840 | 14860 | ||
5500 | 75 | 62 | 56 | 2860 | 15860 | ||
6000 | 79 | 65 | 59 | 2870 | 16860 | ||
FHE(800)-30 (4800person/h) Speed:0.5m/s | 3000 | 59 | 52 | 47 | 2750 | 10900 | |
3500 | 63 | 56 | 50 | 2780 | 11890 | ||
4000 | 67 | 60 | 54 | 2810 | 12880 | ||
4500 | 71 | 64 | 57 | 2830 | 13870 | ||
5000 | 74 | 68 | 60 | 2840 | 14860 | ||
5500 | 82 | 74 | 66 | 2860 | 15860 | ||
6000 | 86 | 78 | 69 | 2870 | 16860 | ||
FHE(1000)-30 (6000person/h) Speed:0.5m/s | 3000 | 63 | 59 | 53 | 2750 | 10900 | |
3500 | 67 | 64 | 57 | 2780 | 11890 | ||
4000 | 71 | 68 | 61 | 2810 | 12880 | ||
4500 | 75 | 73 | 65 | 2830 | 13870 | ||
5000 | 83 | 79 | 71 | 2840 | 14860 | ||
5500 | 87 | 84 | 75 | 2860 | 15860 | ||
6000 | 92 | 88 | 79 | 2870 | 16860 | ||
30° Escalator Construction Layout Drawing | |||||||
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.