Add to Cart
WITTUR elevator gearless traction machine with 400mm sheave diameter
30kn Shaft Load WITTUR Gearless Traction Machine Home Elevator Parts 1.0m/S Speed
630~1050KG | 800~1150KG | |||||||
Rated loads up to(kg) | 630 | 800 | 1000/1050 | 800 | 1000 | 800 | 1000 | 1150 |
Rated torque(N.m) | 420 | 535 | 670 | 540 | 670 | 600 | 740 | 740 |
Traction sheaveΦ(mm) | 400 | 400 | 400 | 400 | 400 | 450 | 450 | 400 |
Rated speed(m/s) | 1.0....2.0 | 1.0...2.5 | ||||||
Shaft load(kN) | 30kN | 35kN | ||||||
CTE test | Y | |||||||
Motor Type | Glearless PM synchronous | |||||||
Net weight(kg) | 330 | 330 | 340 | 330 | 360 | 380 | 390 | 370 |
MRL solution | Applied | |||||||
Installation | ONLY vertical installation inmachine room or top of the shaft |
Features
·Special housing design provides stable and high structural
rigidity. Design is verified FEM and physical mechanical test.
·Designed by outer rotor. Possible to generate bigger torque with
low noise and vibration. Provides comfortable ride.
·Solid construction for permissible shaft load Fs at the traction
sheave up to 35kN
·Safety brake system with electro-magnetical release, provides min.
2×950Nm
·CTE test approved according to GB7588 and TSG T7007
·Groove profiles according to lift system
·Perfect rated motor, use of high - performance permanent magnet,
degree of protection IP40, insulation class 155℃ (F), temperature
control
·Motor with 2 times overload capacity ; max. travelling height up
to 120m
·EC type-examination certificate according to EN 81-20/50, can be
used for UCM solution
·Inverter compatible measuring device, rigid coupling or
intergrated. (e.g. ECN 1313; ERN 1387; TS5213N2503;
EI53C9.25-2048-SA5N2T)
·Variable options regarding voltage, speed, torque, braking torque
and traction sheave parameters
·The braker passed 2 million times braking. After the test, its
performance is still in specification. Safety is guaranteed.
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.