Add to Cart
Load 1600kg Hairline stainless steel frame for Hospital Elevator
Load 1600kg Hospital Lift Stainless Steel Frame Side Opening With Accurate Door Motor Control
Love design, deep care
Combining the elevator experience from both doctors and patients,
our hospital elevator specially designs big handrail, Braille
button and mirror in car for the disabled and bed car, and brings
convenience for more passengers.
High- efficient carriers, perfect medical space
According to occupant comfort, we adopt accurate door-motor control
technology to regulate speed in real time, to realize zero to zero
precision of leveling and to ensure that people and bed could
easily get in and out of the elevator.
We adopt 64-bit full computer control system to optimize route of
elevator, shorten waiting time of medical workers, patient and
their relatives, and coordinate with the needs of medial
environment fficiently.
Warm environment, healthy and green way
By using soft decorated car material to create warm and comfortable
environment for passengers.
By using antiseptic device with positive and negative ion group to
powerfully
decompose the harmful substances in the air, purity environment in
car and increase comfort.
Specification parameter of hospital elevator
Load | Speed m/s | Car size(mm) | Door opening size(mm) | Hoistway size(mm) | ||||||
CW | CD | CH | OP | OPH | HW | HD | K Overhead height | Pit depth | ||
1600 | 1 | 1400 | 2400 | 2500 | 1100 | 2100 | 2500 | 2850 | 4450 | 1550 |
1.5 | 4600 | 1600 | ||||||||
1.75 | 4650 | 1650 | ||||||||
1600 | 1 | 1400 | 2400 | 2500 | 1200 | 2100 | 2300 | 2850 | 4450 | 1550 |
1.5 | 4600 | 1600 | ||||||||
1.75 | 4650 | 1650 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.