AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute

Brand Name:AAREAL
Certification:ISO9001:2015
Model Number:AT200tap
Minimum Order Quantity:1 Set
Delivery Time:1~30 work days after order confirmed
Payment Terms:T/T, L/C, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Xinxiang Henan China
Address: No. 107, North of Dingguo Village, Xinpu Road, Muye District, Xinxiang City, Henan Province, China
Supplier`s last login times: within 32 hours
Product Details Company Profile
Product Details

AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute


Overview of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:
AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute (driven by synchronous belt) made by AAREAL company is in accordance with international products. The working parameters meet the national standards. With test sieve and sample sieve, it can be used for metallurgy, chemical industry, abrasive, super hard materials, feed, food, medicine and other industries screening production and inspection of the powder materials.

The AT200tap rotap test sieve shaker can be equipped with sound-proof cover or shield according to the requirement.


Working Principle of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:

The motor drives the gear speed change through the synchronous belt, making the main shaft rotate. And then the main shaft drives the eccentric wheel to make the slide plate drive the test sieve shake left and right. At the same time, it drives the top gear rotate, strike the hammer and slap the test sieve, making materials in the test sieve and sample sieve screen layer by layer. So people can accurately obtain the materials of multiple particle size ranges at the same time, achieving accurate and rapid screening purposes.


Technical Parameters of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:

1. This machine is running intermittently. This machine is a intermittent running and 8-hour single-shift operating laboratory equipment.

2. The screen frame of this machine is selected to meet GB/T 6003.1-1997 standard.

3. Motor Power: 0.18KW

4. Number of Revolution: 290±6 times/min

5. Tapping Times: 156±3 times/min

6. Tapping Height: 38±6mm

7. Rotation Distance: 25mm

8. Power Supply: 220V/50HZ or 220V/60HZ


NO.NameValueUnit
1Diameter300, 200, 150, 100, 75mm
2Layer5~7Layer
3Shaking Times290±10times/min
4Tapping Times156±10times/min
5Reciprocating Trip25mm
6Tapping Height38±6mm
7Power370W
8Voltage380, 220V
9DimensionsH700*L460*W420mm
10Weight100KG
Note: All technical data and dimensions of our products shall be subject to physical objects.

Features of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:

1. The reproducibility of the test result is good.

2. Simple operation, free of refueling, clean, hygienic and convenient.

3. It can be equipped with 200mm or 205mm sieves, 1~8 layers.

4. Complete synchronous belt conduction power, quick and easy maintenance.

5. Selection of high quality accessories, reasonable structure, low failure rate.

6. Accurate transmission, good consistency.

7. Long life and low maintenance cost.

8. Sound protecting cover can be installed to avoid noise.

9. High screening efficiency.

10. Clean.


Advantages of Tap Sieve Shaker:
1. High-Efficiency Sieving Mechanism:
Combines horizontal circular motion (278 oscillations/min) and vertical tapping action (150 taps/min) to enhance particle separation efficiency, significantly reducing manual operation time.


2. Compatibility & Standardization:
Supports 200mm (8-inch) and 300mm (12-inch) standard sieve stacks, compatible with full/half-height sieves. Complies with international testing standards like ASTM, ideal for certified applications (e.g., foundry sand fineness analysis).


3. Durable Industrial Design:
Features a maintenance-free metal frame for heavy-duty use. Some models support auto-adjustment for 110-220V power supply, ensuring global adaptability.


4. User-Friendly Operation:
Equipped with touch panels or mechanical controllers, and multi-task displays (e.g., Station 2 remote control) for simplified parameter setup and workflow management .


Application of Rotap Test Sieve Shaker for Silica Sand Laboratory Particle Size Analysis​:

Our AT200tap rotap test sieve shaker can be used in diamond and other materials of high value, requiring accurate screening of the abrasive industry. This kind of sieve shaker is widely used in metallurgy, powder, chemical, pharmaceutical, building materials, geology, feed, defense and other departments of scientific research and production, laboratory, and quality inspection room, for particle and powdery materials granular structure and sundries amount of standard screening, filtering and inspection sieve test. The device is equipped with timing device to ensure the accuracy and repeatability of the user test results.


Contact: Ms. Magie

E-mail: sale@aarealmachine.com

magiecn@gmail.com

WhatsApp/WeChat: 0086-15637361027

Website: https://www.aarealmachine.com

China AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute supplier

AT200tap 0~99 Minutes 1~8 Sieves Tap Sieve Shakers for Accurate And Consistent Particle Analysis Testing 278 Oscillations 150 Taps Per Minute

Inquiry Cart 0