Dental Perfect Rotary File Systems Heat Treated Files T Flex Assorted

Brand Name:Perfect
Certification:ISO,CE,FDA,FSC
Delivery Time:15 days since receiving payment
Payment Terms:T/T, Paypal, Western Union
Place of Origin:Shenzhen, China
Price:Negotiable
Contact Now

Add to Cart

Active Member
Location: Shenzhen Guangdong China
Address: Rm 1810, Floor18., Bldg. A, Baoneng Huigu, Liujin Plaza, Intersection of North Bao'an Rd. & Liyuan Rd., Luohu District, Shenzhen City,China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Rotary Files Dental Instruments Heat-treated T-Flex Assorted

Section
LengthL17L15L20L25L25
SizeOpenerNevigateT-20T-25/.04T-25/.06
Torque2.5 N·cm1.5 N·cm2.0 N·cm2.5 N·cm2.5 N·cm
Rotary Speed350-400 (rpm)300-350 (rpm)350-400 (rpm)350-400 (rpm)350-400 (rpm)
Sterilization≤134℃
Cross Section






2. Use of Protocol

1) Create the glide path. Establish Working Length ;Scout the coronal 2/3 with #10 or #15 with hand files. Gently work these instruments until glide path is confirmed.(Using Nevigate optionally)

2) Widen the orifice of root canal by Opener.Remove dentine,brush canal wall by circumferential operating motion.

3) Glide path with Nevigate if necessary.

4) Remove and shape the canals with T20 and T25/.04 to the Working Length.

5) Required T25/.06 for larger canals.

3. Terms for sterilization:

1. Steam Sterilize at 134°C(273°F) / 2,1 bars / 18 min.for root canal instruments and filling.

2. Do not employ high pressure steam sterilization apparatus which provides heat above 200 including drying process.

3. If the instrument needs to be reused, clean foreign substances thoroughly and then conduct sterilization.

4. Speaking of medical detergent, completely follow the instruction guide by its manufacturer .

5. Throw away properly the product when damaged or it has deterioration in performance.

4. Packagings

1. Single packing : 6 pcs /pack (Opener~T25/.06)

2. Assorted packing : 1 pcs from each size/pack (Opener-T25/.06)

5. Storages and duration of use

1. Do not store instruments under high temperature, humidity and avoid direct sunlight.Keep it at room temperature and keep off liquids.

2. Be careful not to damage or create a pierce to packaging materials.

3. This product is subject to be adjusted without prior notice. Conduct first-in first-out method for stock management.

4. Do not expose the instrument to a germicidal lamp which can lead to instrument deterioration.