Study the SAFETY RULES carefully before installing, operating or
servicing this equipment. Become familiar with this Owner’s Manual
and with the unit. The CHP can operate safely, efficiently and
reliably only if it is properly installed, operated and maintained.
Many accidents are caused by failing to follow simple and
fundamental rules or precautions.The manufacturer cannot anticipate
every possible circumstance that might involve a hazard. The
warnings in this manual, and on tags and decals affixed to the unit
are, therefore, not all inclusive. If a procedure,work method or
operating technique is used that the manufacturer does not
specifically recommend,ensure that it is safe for others. Also make
sure the procedure, work method or operating technique utilized
does not render the CHP unsafe.
HIGH ALTITUDE OPERATION
At high altitude, the standard gas mixer will be excessively rich.
Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller
diameter main fuel jet in the mixer and readjusting the pilot
screw. If you always operate the engine at altitudes higher than
5000 feet (1500 meters) above sea level, have an authorized CHP
dealer perform this mixer modification.
Even with suitable mixer jetting, engine horsepower will decrease
approximately 3.5% for each 1000 foot (300 meter) increase in
altitude. The effect of altitude on horsepower will be greater than
this if no carburetor modification is made.
CHP Main Specifications
Item | Model | SP12B | |
fuel | — | Biogas | |
marks | — | Synchro CHP | |
CHP | electrical output(KWe) | kVA/kWe | Continuous Power |
15/12 | |||
thermal output(KWe) | kWt | 25 | |
electrical efficiency | % | 25.84% | |
thermal efficiency | % | 53.83% | |
overall efficiency | % | 79.67% | |
frequency | Hz | 50 | |
voltage | V | 380/220 | |
gas inlet pressure | kPa | 1-10 | |
dimension (soundproof type) | mm*mm*mm | 1800*780*1020 | |
net weight | kg | 650 | |
Biogas consumption | m3/kW.h | 0.54 | |
Biogas consumption for one hours | m3/h | 6.48 | |
db(A)@7m | — | 57 | |
Certificate | — | CE | |
water-water heat exchanger | — | SWEP | |
water-exhaust heat exchanger | — | designed by our own factory/made of full stainless steel | |
ignition system | — | Impco | |
speed governor | Woodward | ||
gas filter | — | Madas | |
zero regulator | — | Maxitrol | |
MCB | — | ABB | |
GCB | — | ABB | |
Controller | ComAp/CZ | ||
Engine | Engine model | — | SP-4Y |
Engine type | — | 4 cylinders,4stroke,water-coolled | |
RPM | — | 1500 | |
Compression Ratio | — | 9.6 | |
Displacement | — | 2.237L | |
Oil capacity | — | 4.2L | |
Charging voltage | — | 12V(DC) | |
Charging current | — | 6A(DC) | |
Starting system | — | Electic-start | |
Alternator | model | — | Meccalte |
phase | — | 3 phase 4 wires | |
insulation system | — | class H | |
protection | — | IP23 | |
Cooling Type | air cooled |
Characters
Environmentally friendly design.
Long time R&D and testing ensure high reliability.
Comprehensive heat insulation to minimize heat loss.
CHP inner pipelines are made of full stainless steel material.
Maximum lower the noise level.
Maintenance friendly thanks to easy access.
For more information about each CHP, please consult with your sales
representative.Thanks.