Add to Cart
60Hz 127V 3 Phase Biogas Generator Set 180KVA 150KW With CE Silent
/ Open Design Biogas Power Plant
Biogas Requirements
Acceptable fuel gas pressure: 3~7kPa, CH4 content ≥55%
Gas low heat value (LHV) ≥25MJ/Nm3. If LHV<25MJ/Nm3, gas engine
power output will be decreased.
Gas doesn't include any free condensation water or free materials
(the size of impurities should be less than 5μm.)
H2S content≤ 100ppm. NH3 content≤ 50ppm. Silicon content ≤ 5 mg/Nm3
Impurities content≤30mg/Nm3, size≤5μm
No free water.
CHP Main Specifications
Item | Model | SP165B | |
fuel | — | Biogas | |
marks | — | Synchro Genset | |
CHP | electrical output(KWe) | kVA/kWe | Continuous Power |
187.5/150 | |||
frequency | Hz | 60 | |
voltage | V | 110/220 | |
gas inlet pressure | kPa | 3-5 | |
dimension (soundproof type) | mm*mm*mm | 2900*1600*1800 | |
net weight | kg | 3500 | |
Biogas consumption | m3/kW.h | 0.42 | |
Biogas consumption for one hours | m3/h | 63 | |
db(A)@7m | — | 59 | |
Certificate | — | CE | |
ignition system | — | Impco | |
speed governor | — | Woodward | |
gas filter | — | Madas | |
zero regulator | — | Kromschroeder | |
MCB | — | ABB | |
GCB | — | ABB | |
Controller | ComAp IC | ||
Engine | Engine model | — | STYER T10 |
Engine type | — | 6 cylinders,4stroke,water-coolled | |
RPM | — | 1800 | |
Compression Ratio | — | 11.0 | |
Displacement | — | 9.726L | |
Oil capacity | — | 24L | |
Charging voltage | — | 24V(DC) | |
Charging current | — | 5A(DC) | |
Starting system | — | Electic-start | |
Alternator | model | — | Meccalte |
phase | — | 3 phase 4 wires | |
insulation system | — | class H | |
protection | — | IP23 | |
Cooling Type | — | air cooled |
Characters
Environmentally friendly design.
Long time R&D and testing ensure high reliability.
Maximum lower the noise level.
Maintenance friendly thanks to easy access.
For more information about the genset, please consult with your