Add to Cart
450V / 750V Flame Retardant Cable Colorful Flexible Copper Conductor
Cable Structure
Conductor : Class 1,2,5 Flexible Copper Conductor
Screen: Mica tape
Insulation: PVC or LSZH PO
Sheath:PVC: (Optional)
Rated Voltage : 450/750V
1. Application
Flexible cable for medium mechanical stresses. Permitted frequent
bending and twisting. Specially suitable for application in
household, kitchens and offices in dry and damp conditions, for
inst. washing-machines, dryers, refrigerators etc., as long as the
cable is adapted to essential specifications of the device. Also
suitable for cookers, i.e. hot devices, on condition that it does
not get in direct contact with hot parts of the device and is not
exposed to heat irradiation. Suitable for fixed installation in
furniture, partition walls, decorative linings and cavities in
prefabricated construction elements
2. Technical data
Temperature range :
during installationi : +5 °C up to +70 °C
fixed installed : -30 °C up to +70 °C
at short circuit of max. 5 s : up to 150 °C
ambient temperature at storage : up to 40 °C
Nominal voltage : Uο/U = 300/500 V
Test voltage : 2000 V
Minimal inner bending radius : 4D for D < 8 mm
5D for 8 - 12 mm
6D for D > 12 mm
corexsection mm2 | conductor structure | External diameter mm | Insulation thickness mm | Sheath thickness mm | Conductor resistance at 20 °C Ω/km | Specific. el. resistance of insulation at 70°C MΩkm |
2x0.75 | 24x0.2 | 5.7-7.2 | 0.6 | 0.8 | 26.0 | 0.011 |
2x1 | 32x0.2 | 5.9-7.5 | 0.6 | 0.8 | 19.5 | 0.010 |
2x1.5 | 30x0.25 | 6.8-8.6 | 0.7 | 0.8 | 13.3 | 0.010 |
2x2.5 | 50x0.25 | 8.4-10.6 | 0.8 | 1.0 | 7.98 | 0.0095 |
3x0.75 | 24x0.2 | 6.0-7.6 | 0.6 | 0.8 | 26.0 | 0.011 |
3x1 | 32x0.2 | 6.3-8.0 | 0.6 | 0.8 | 19.5 | 0.010 |
3x1.5 | 30x0.25 | 7.4-9.4 | 0.7 | 0.9 | 13.3 | 0.010 |
3x2.5 | 50x0.25 | 9.2-11.4 | 0.8 | 1.1 | 7.98 | 0.0095 |
3x4 | 56x0.3 | 10.5-13.1 | 0.8 | 1.2 | 4.95 | 0.0078 |
4x0.75 | 24x0.2 | 6.6-8.3 | 0.6 | 0.8 | 26.0 | 0.011 |
4x1 | 32 x 0,20 | 7,1 - 09,0 | 0.6 | 0.9 | 19.5 | 0.010 |
4x1.5 | 30 x 0,25 | 8,4 - 10,5 | 0.7 | 1.0 | 13,3 | 0,010 |
4x2.5 | 50 x 0,25 | 10,1 - 12,5 | 0,8 | 1.1 | 7,98 | 0,0095 |
4x4 | 56 x 0,30 | 11,5 - 14,3 | 0,8 | 1.2 | 4,95 | 0,0078 |
4x6 | 84 x 0,30 | 14,7 | 0.8 | 1.2 | 3,30 | 0,0068 |
5x0.75 | 24 x 0,20 | 7,4 - 9,3 | 0.6 | 0.9 | 26.0 | 0.011 |
5x1 | 32 x 0,20 | 7,8 - 9,8 | 0.6 | 0.9 | 19.5 | 0,010 |
5x1.5 | 30 x 0,25 | 9,3 - 11,6 | 0.7 | 1.1 | 13.3 | 0,010 |
5x2.5 | 50 x 0,25 | 11,2 - 13,9 | 0.8 | 1.2 | 7,98 | 0,0095 |
Operating characteristics
1, Long-term allowable operating temperature of cable conductor ≤70°C
2, Highest working temperature of cable in case of short circuit (the
longest lasting time is not over 5s):≤300mm2 cable conductor ≤160°C, ≥300 mm2 cable conductor≤ 140°C.
3, The laying temperature should over 0℃,Permissible bending radius of
cable:for single core unarmored cable, should be no less than 20 times of it’s outer diameter ; for multi-core unarmored cable, should be no less than 15 times of it’s outer diameter
4, With flame-retardant property,ZA,ZB,ZC,ZD are 4 types
5, The product is applicable for AC 50 Hz transmission and
distribution lines with rated voltage of 0.6/1KV