Ventilated Facade Tile Terracotta Panels For Cladding Wall System
Introduction
(A) Open Systems, heat & sound insulation
Terracotta panel adopt open systems dry-hanging installation help
to protect architectural main structure erosion from inclement
weather and air pollution, to prevent the wall cladding producing
sediment, keeping curtain wall beautiful. At the same time this
installation way can effectively reduce the heat transfer
coefficient, effectively improve the acoustic behavior of building
walls. The whole system can be heat insulation, sound insulation,
ventilation, humidity insulation effect, also can effectively
improve the indoor temperatures in summer, eliminating the thermal
bridge effect and save energy consumption.
(B) Waterproof & anti-collision design, Anti-pressure &
seismic
Install principle carries on spliced design according to principles
of equal pressure rain-screen. It uses a special design of EPDM
tape between the sub-sutural of the two interfaces. This way can
effectively reduce the intrusion of rain, prevent terracotta panel
from lateral displacement, and prevent collisions between adjacent
terracotta panels. At the same time, after improvement terracotta
panel system improves the terracotta panel wall press resistance,
earthquake protection up to 10 degrees or more, particularly
suitable for buildings which require resisting wind pressure and
seismic.
(C) Add installation gasket, single piece can be replaced
Between terracotta and clamp parts, clamp and rail are separated by
flexible insulating gasket, to improve the anti-seismic of the
system, to avoid the solution of electrolytic corrosion among the
different metal material, and can also eliminate the noise and
distortion. And broken terracotta panel can be physical damage
without dismount the installed terracotta panel, single piece can
be replaced easily.
(D) Sophisticated workmanship, back ventilation
The processing of terracotta panel uses advanced technology
control, surface flat and dimensional stabilization, can meet the
maximum design needs of wall closed edge and closed ends. No matter
the screen or corners or other parts of, it can maintain the
vertical of curtain wall facades coherent, natural and beautiful.
Meanwhile, humidity of building can be taken away by flowing air
behind the wall space to avoid producing condensation water and
keep the exterior walls dry.
Application
Specification
Inspection Items | Tchnical Parameter (Thickness:18mm) | Reference Standards |
Water Absorption Rate | 3≤average value≤8% | JC/T 1080-2008 |
Dry Weight | ≤33kg/m2 | ---- |
Freezing Resistance | No Crack or Flake after 100 times test in -30°C~30°C | JC/T 1080-2008 Q/JHTJ001-2009 |
Breakage Strength | ≥2.98KN | JC/T 1080-2008 |
Rupture Modulus | ≥14MPa | JC/T 1080-2008 |
Poisson Ratio | 0.33 | ISO17561 |
Modulus of Elasticity | 0.305x105 | ISO17561 |
Fire Resisting Property | A Degree | JC/T 1080-2008 |
Low Concentration Acid and Alkali Resistance | UA Degree | GB/T4100-2006 |
High Concentration Acid and Alkali Resistance | ULA Degree | GB/T4100-2006 |
Radio-Activity | AI Degree | GB6566-2001 |
Seismic Behavior | ≥10 | GB/T18575, GB5011 |
Wind Load | Positive Pressure: 5.0KPa Negative Pressure: 5.0KPa | GB/T21086-2007 |
Sound Proof | Reduce Noise more than 9db | ---- |
Thermal Shock Resistance | No crack or explode after 10 times test | JC/T 1080-2008 |
Bending Strength | 13.5MPa | GB/T4741 |
Density | 2.0--2.4g/cm3 | ---- |
Expansibility | 0.02mm/m | GB/T4100-2006 |
Coefficient of Heat Conductivity | 0.264W/m.K | JC/T 1080-2008 |
Surface Quality | No Flaw when see from 1 meter away | JC/T 1080-2008 |
Plane Deformation Capacity | Fifth Degree | GB/T21086-2007 |
Hanging Strength | average value≥1.34KN | GB/T9966.7-2001 |
Stain Resistance | 3 Degree | GB/T4100-2006 |
Linear Thermal Expansion | 5.8x10-6C-1 | GB/T4100-2006 |