F1/F2 Terminal 12v 9ah VRLA Regulated Lead Acid Battery

Brand Name:G-Tech power
Certification:CE and ROHS
Model Number:GT12-9
Minimum Order Quantity:1000
Delivery Time:30 days
Payment Terms:T/T, Western Union, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 1003 Yuemeite Building No.1 Gaoxin South 7th Road, High tech Industrial Park, Yuehai Street, Nanshan District, Shenzhen
Supplier`s last login times: within 21 hours
Product Details Company Profile
Product Details

12V 9Ah lead acid battery for ups backup power

GT12-9.0
(12V9Ah)
Features:
Structure: compact design, shorter internal connectors between cells, thus low internal resistance
Plate: Pasted flat type, with patent formula of AM
Terminal: Two or more types terminals are convenient for selection
Vent system: Gas can be vented through flame arrester
Separator: Using improved AGM separator, make lower resistance higher assembling pressure to increase cycle life
Battery case: Made of high strength ABS and UL94-V0 is optional
Terminal sealing: Double sealing technics(mechanical+epoxy gule)
Application:
Small UPS
Emergency Light
Security System
Toys
Illumination light
Fire alarms
Medical equipments
Specification
Cells Per Unit
6
Voltage Per Unit
12
Capacity
9Ah@20hr-rate to 1.75V per cell @25 C
Weight
Approx. 2.55 Kg
Max. Discharge Current
90A (5 sec)
Internal Resistance
Approx. 18 mΩ
Operating Temperature Range
Discharge: -20 C~60 C
Charge: 0 C~50 C
Storage: -20 C~60 C
Normal Operating
Temperature Range
25 C±5 C
Float charging Voltage
13.7 to 13.9 VDC/unit Average at 25 C
Recommended Maximum
Charging Current Limit
2.16 A
Equalization and Cycle Service
14.6 to 14.8 VDC/unit Average at 25 C
Self Discharge
Up to 6 months at 25 C. Self-discharge ratio less than 3%
o per month at 25 C. Please charge batteries before using.
Terminal
Terminal F1/F2
Container Material
A.B.S. (UL94-HB) , Flammability resistance of UL94-V1
can be available upon request.

Discharge Current VS. Discharge Voltage
Final Discharge
Voltage V/cell
1.75V
1.70V
1.60V
Discharge
Current (A)
A≤ 0.2C
0.2C < A < 1.0C
A ≥ 1.0 C

Charging Method:
Constant Voltage
-0.2Cx2h+2.4~2.45V/Cellx24h,Max. Current 0.3CA
Constant Current
-0.2Cx2h+0.1CAx12h
Fast
-0.2Cx2h+0.3CAx4.0h


Charge the batteries at least once every six months, if they are stored at 25 C
Avoid battery over discharge, especially battery sereis connection use..