SDM320C Single Phase Multi-function Remote Control Energy Meter for Energy System

Description:

The SDM320C is a single phase multifunction remote control direct connect meter. It has a built-in relay, you can remote control turn on or off when you work in front of computer. Besides, it has alarm system, the relay will open automatically when the parameter reachs the alarm value. There are 26 types alarm object and alarm value you can set by rs485. SDM320C measures and displays the characteristics of single phase two wires (1p2w) supplies, including voltage, current, frequency, power, active and reactive energy, imported and exported. Energy is measured in terms of kWh, kvarh. In order to measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product.


SDM320C supports max. 100A direct connection, saves the cost and avoid the trouble to connect external CTs, giving the unit a cost-effective and easy operation. Built-in interfaces provides pulse and RS485 Modbus RTU outputs. Configuration is password protected.


Features:

  • Measures KWh Kvarh, KW, PF, HZ, V, A, etc.
  • Built-in relay, remote control switch
  • Alarm system
  • Rs485 modbus
  • Din rail mounting 35mm
  • 100A direct connection
  • Better than class 1 / 0.5s accuracy

Unit Characteristics


The Unit can measure and display:

  • Line voltage
  • Frequency
  • Line Currents
  • Power, maximum power demand and power factor
  • Active energy imported and exported
  • Reactive energy imported and exported

The unit has password-protected set-up screens for:

  • Changing password
  • Demand Interval Time(DIT)
  • Pulse Output Duration
  • Backlit Lasting Time
  • Display Scroll Times

Product Details:

Electrical characteristics
Type of measurement
RMS including harmonics on three phase AC system ( 3P+N)
Measurement accuracy
Power
IEC 61557-12 Class 0.5
Active Energy
IEC 62053-22 Class 0.5S, IEC 61557-12 Class 0.5
Reactive Energy
IEC62053-23 Class 2, IEC 61557-12 Class 2
Frequency
±0.1%
Current
±0.2%
Voltage
±0.2%
Power Factor
±0.01
Data Update Rate
1 second nominal
Power Consumption Per Phase
≤2W/10VA
Max Reading
999999.99kwh/kvarh
Input-Voltage
Operational Voltage
176-276VAC
Un
230/400VAC
Impedance
1M Ω
Frequency Range
50/60H
Input- Current
Basic Current
5(100)A
Operational Current Range
0.4%Ib~Imax
Over Current Withstand
30Imax for 0.01S
Impedance
<1 mΩ

Mechanical Characteristics
IP Degree of Protection (IEC 60529)
IP51 front display
Dimensions (WxHxD)
76x96.5x76.5
Mounting Type
35mm Standard DIN Rail mounting
Material of meter case
Self-extinguishing UL 94 V-0
Mechanical environment
M1

Communications
Interface standard and protocol
RS485 and MODBUS RTU
Communication address
1~247
Transmission mode
Half duplex
Data type
Floating point
Transmission distance
1000m Maximum
Transmission speed
1200bps~9600bps
Parity
None (default), Odd, Even
Stop bits
1 or 2
Response time
<100 mS

Environmental Characteristics
Operating Temperature
-25 to 55°C
Storage Temperature
-40 to 70°C
Humidity Rating
<95% RH at 50 °C (non-condensing)
Pollution Degree
2
Altitude
2000m

Electromagnetic Compatibility
Electrostatic Discharge
IEC 61000-4-2
Immunity to Radiated Fields
IEC 61000-4-3
Immunity to Fast Transients
IEC 61000-4-4
Immunity to Impulse Waves
IEC 61000-4-5
Conducted Immunity
IEC 61000-4-6
Immunity to Magnetic Fields
IEC 61000-4-8
Immunity to Voltage Dips
IEC 61000-4-11
Radiated Emissions
EN55011 Class A
Conducted Emissions
EN55011 Class A
Harmonics
IEC 61000-3-2

Safety
Measurement Category

Per IEC61010-1 CAT III

Current Inputs
Require external Current Transformer for Insulation
Over voltage Category
CAT III
Dielectric Withstand
As per IEC 61010-1 Double Insulated front panel display
Protective Class
II

Wiring diagram:


Dimensions:


Installation:


China Remote Control Single Phase Electric Meter Modbus RTU SDM320C For Energy System supplier

Remote Control Single Phase Electric Meter Modbus RTU SDM320C For Energy System

Inquiry Cart 0