

Add to Cart
the feature for AL-40S is as below:
1, Unique Fresnel lens, effectively increase the sensitivity
2, pet immunity
3, key components are imported from Japan, such as Japan made relay which can do ON/OFF for 1billion times
4, a under window which can reduce the blind detect area
5, with bracket
1. SPECIFICATIONS
MODEL | AL-40S |
Detection Range | 40ft x 56ft (12mx17m) |
Input Voltage | 10 ~ 16VDC |
Current Drain | 25mA(max.) at 12VDC |
Pyro Type | Dual Element |
Pulse Count | Qualified Motion Analysis - 2 or 4,Selectable |
Warm- up Period | Approx. 45 sec |
Alarm Period | Approx. 2.5 sec |
LED Indicator | Red Alarm LED(Selectable On / Off) |
Alarm Output | N.C., 24V DC 0.5A max. |
Tamper Output | N.C.,Open when cover is removed. 30V DC,0.5A max. |
Mounting Height | 6.5 ~ 8.5 ft (2~2.6m) |
Operating Temp. | 14°F ~ 131°F (- 10℃~55℃) |
Environmental | 95% max. |
Weight | 3.0 oz (83.5g) |
Dimensions | 3.9"Hx2.5"Wx1.7"D (98.0x64.0x43.0mm) |
2. DIMENSIONS
4. DETECTION PATTERN
8. TROUBLE SHOOTING AND MAINTENANCE
TROUBLE | TROUBLE CAUSE | REMEDY |
Unit does not power up. | No or low input power. | Apply proper input voltage. |
Input power polarity reversed. | Correct wiring polarity. | |
Alarm LED does not light. | LED jumper is set to “LED OFF”. | Set LED jumper to “LED ENABLE”(See Section 3). |
Incorrect sensor mounting height. | Increase /decrease mounting height. | |
Pulse Count setting incorrect for secured area. | Set pulse count jumper to suit the required detection characteristics. | |
Alarm LED/Relay triggers with out movement in detection area. | Unsecured environment:Animals / rodents in detection area . | Block access of animals / rodents. |
Heater/air conditioning equipment in sensor view. | Re-aim sensor. | |
Direct sun or headlights in sensor view. | Add curtain/shade to block light sources. | |
LED indicates alarm, no alarm output. | Incorrect wiring at alarm output terminals. | Correct wiring fault. |
Lightning damage. | Replace sensor. | |
Alarm LED on constantly, no fault in protected area or wiring. | Defective unit. | Replace sensor. |
Unit continues to operate after the input power has been disc- onnected. | The wire to the “ - ” power input was disconnected, the“ + ” is still connected. The power can now find a return path through the Alarm Output protection device and alarm wiring. | Disconnect wire from the “ + “ power input. |
MAINTENANCE
INSPECTION:An inspection of this unit should be made periodically,consisting of,but not limited to all mounting,wiring,and the condition of the interior area and components.
CLEANING: Clean the plastic parts of this unit with a soft , clean , cloth dampened with water.
TESTING: This unit should be tested routinely for proper operation. At a minimum,operation should be fully checked yearly.
NOTES: This detector is designed to be incorporated into an alarm system. As it is part of a system, ALEPH cann’t assume responsibility for theft or damage if the system fails to operate.
FAQ:
Q: 1. Can I have a sample order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q: 2. What is the lead time?
A:Sample needs 1-3 days, mass production time needs 10-15 days for order less than 5000 pcs.
Q: 3. How do you ship the goods and how long does it take arrive?
A: for samples, We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive.
for cargos, you can choose sea or airline service by your needs.
Q: 4. How to proceed the order if I have logo to print?
A: Firstly, we will prepare artwork for visual confirmation, if the color and position are alright, we would make sampling first from silk print factory and take picture for your second confirmation before mass production.
About US
International leading alarm security system, door magnetic contacts, smart home security products, smart sanitary products