QT-40 Quad Element Outdoor Indoor Microwave PIR Detector With Pet
Immunity For Intrusion Alarm
Description
Microwave Freq. | 10.525 GHz, pulsed |
Input Voltage | 10 to 16 VDC, 12 VDC nominal |
Input Current | 15 mA max. (SL model 30 mA), 11 mA quiescent (approx.) |
Pyro Type | Dual Element |
Pulse Count | Jumper selectable: PC2, PC4 |
Warm-up Time | < 50 seconds |
Alarm Period | 2.4 seconds, retriggerable |
Visual Indicator | Red Alarm LED (Selectable On / Off) |
Alarm Output | NC, solid state, 19 VDC, 100 mA, 13 ohms resistance typ. |
Tamper Output | NC, dry contact, 30 VDC, 500 mA, 5 W max. |
Mounting Height | 7 to 8.5 ft (2.1 to 2.6 m) |
Operating Temp. | 14° to 131° F (-10° to+55° C) |
Environmental | 95% humidity non-condensing |
Weight | 3.7 oz / 105 g |
Dimensions | 4.8” H x 2.5” W x 1.7” D / 12.2cm x 6.4cm x 4.3cm |
Available with 40-foot and 60-foot protection patterns, QT Series
intrusion detectors provide high quality PIR+microwave security at
an outstanding value. Aleph’s unique “QT” signal processing
evaluates PIR and microwave information while factoring in ambient
temperature and light for superior “Quad-Tech” performance. The
Security Light feature adds safety lighting, providing a soft white
light when triggered in a darkened room.
Installation
Select an installation height between 7 ft. (2.1 m) and 8.5 ft.
(2.6 m). Optimum mounting height is 7.5 ft. (2.3 m). Avoid aiming
the intrusion detector towards windows, areas exposed to direct
sunlight, and heating/cooling outlets. For best performance,
position the detector so its field of view is unobstructed, and the
anticipated path of an intruder will cross the PIR beam pattern.
Separate the front and rear covers by first backing out the cover
latch screw three to four full turns. Using a small screwdriver or
similar tool, release the cover latch. To remove the PCB, push the
PCB latch away from the board while grasping a terminal block and
pulling the PCB out of the cover. Do not pull on the microwave
module. Refer to Figures 1 and 2, below.
Wire the detector to the control panel using 18 to 22 AWG
conductor, standard non-shielded cable. Avoid running alarm wiring
parallel to AC wiring. Wiring knockouts and wire channel are
provided in the rear cover for unobtrusive wiring. Terminal block
configuration is shown in Fig. 3, below.
Adjustments & Settings
Prior to mounting the detector, configure jumper settings as
required (see Fig. 2, below).
Pulse Count: When Pulse Count jumper is covering both pins, PC is set at 2:
two to three normal steps are required to trigger an alarm. Parking
the PC jumper on one pin (or removing jumper) sets PC to 4: four to
five steps will trigger an alarm.
50 / 60 Hz: Set to AC mains frequency for fluorescent light immunity. Jumper
installed on both pins programs the detector for 60 Hz immunity.
Parking the jumper on one pin (or removing jumper) programs the
detector for 50 Hz immunity.
LED Enable: When Jumper is covering both pins, the Alarm LED is enabled. The
Alarm LED glows through the lookdown lens when an alarm is
signaled at the Alarm Output terminals. LED brightness
automatically increases when light level in detection area is high.
As room light dims so does the LED brightness. Parking the jumper
on one pin (or removing jumper) disables the Alarm LED but has no
effect on the alarm output.
Microwave Sensitivity: Microwave Sensitivity Adjustment is set to the fully clockwise
position at the factory for maximum sensitivity (range). The
installation in a small room, it may be desirable to reduce
microwave sensitivity. Turn the Microwave Sensitivity Adjustment
(Fig. 2) counter-clockwise to reduce sensitivity. Setting the
adjustment to minimum (fully counter-clockwise) reduces sensitivity
to approximately one-third of its maximum value.
SL Front / SL Down: -- Included on Model QT-40SL -- These jumpers independently enable
and disable Security Light “Front” and “Down”
functions. SL Front controls a single white LED which shines
through the main lens. SL Down controls two white LEDs aimed
downward through the lookdown lens. When enabled, Security Light
will turn on when motion is detected and room light is dim.
Continued motion will cause Security Light to remain on. Light will
turn off approximately 10 seconds after motion ceases. NOTE: The
red Alarm LED is suppressed while SL is operating.
Compliance Information:
- All wiring should be in accordance with NEC, NFPA 70.
- Product should be inspected and tested annually.
- The included 100lb. Animal Immune lens and Security Light feature
have not been investigated by Underwriters Laboratories Inc.
- Indoor use.
- The unit is intended to be connected to a compatible Listed power
supply that provides a minimum of 4 hours standby time.
- 50/60 Hz jumper should be set to 60Hz (jumper installed) for N.
American installations.
- Maximum microwave sensitivity and Pulse Count 2 are to be used for
UL applications.
Protection Patterns
Troubleshooting
>
Trouble | Likely Causes | Remedy |
Unit does not power up. | No or low input power. Input power polarity reversed. | Apply proper input voltage. Correct wiring polarity. |
|
Alarm LED does not light. | LED jumper is set to “LED OFF”. Incorrect sensor mounting height or aiming. Pulse count setting
incorrect for protection area . | Set LED jumper to“LED ENABLED”. Alter the mounting height or aim. Set pulse count jumper to suit the detection requirements. |
|
Alarm LED / Relaytriggers without movement in the protection area. | Animals / rodents in protection area. Heating or air conditioning
outlets in sensor view. If using the optional animal immune lens: Pet access to furniture
or room fixture in view of the detector. | Block access of animals / rodents. Re-aim sensor.
Ensure that pets can not climb up onto furniture / fixtures in
protection area. |
|
An alarm is indicated at the LED but not at the alarm output. | Incorrect wiring at the alarm output terminals. Lightning damage. | Correct the wiring fault. Replace sensor. |
|
Alarm LED on constantly, no fault in protected area or wiring . | Defective unit. | Replace sensor. |
Unit continues to operate after input power has been disconnected. | The wire to the power input was disconnected, the “+” is still
connected. The power is finding a return path through the Alarm
Output protection device and alarm wiring. | Disconnect wire from the “+” power input. |
Maintenance
- INSPECTION: An inspection of this unit should be made periodically,
including, but not limited to all mounting, wiring, and the
condition of the interior area and components.
- CLEANING: Clean the external plastic parts of this unit with a soft, clean,
cloth dampened with water.
- TESTING: This unit should be tested routinely for proper operation. At a
minimum, operation should be fully checked yearly.
Company Profile
AIN Technology (Shenzhen) Co., Ltd. is an international enterprise
which is exclusively designated and authorized by ALEPH Group to
sell ALEPH brand security products, door magnetic switches, and
Panther 4000, which is a wireless security systerm. AIN has set up
production bases and branches in China (Shenzhen, Zhuhai), Japan,
Europe, the United States and many other countries.
ALEPH brand alarm equipment, door magnetic switches and Baoping'an
smart home security products which are researched and developed by
AIN Technology have been all over the world. Especially the
independently researched and developed active infrared intrusion
detector which is the first in the world has been leading the
development and innovation of the infrared industry for China, even
the world.
AIN has a professional R&D team and high-quality management
personal, annually invests more than 15% of the operating income in
research and development and has two major product series of
“ALEPH” and AIN.
AIN has won the honor of a&s Top Ten International Brands for
ALEPH security products for many years. Furthermore, AIN is the
designate supplier of infrared detection products of Vanke Group.
Its products have been widely used in government agencies,
airports, nuclear power plants, factories, residential estates and
so on.
AIN has passed the following international quality system
certifications : ISO9001:2008, ISO14001: 2004 and
QC080000:2012; product certification: CCC, CQC, UL, CE, FCC, etc.