Product Details
REQUEST-TO-EXIT Passive Infrared Sensor 0-95% non-condensing
Humidity REQUEST-TO-EXIT Passive Infrared Sensor
1. SPECIFICATIONS
Supply Voltage | 12-24VDC or VAC . |
Supply Current | 18-30mA@12-24VDC,45-80mA@12-24VAC |
Relay Output | 2C Contact(N.C/N.O) , 24VDC 1A Max. |
Detection Type | Passive infrared |
Relay Hold Time | 0.5-64 seconds |
LED Indication | Red |
Range | Coverage 12x5 ft at 7ft high,30x12 ft at 15 ft high(Adjustment ) |
Operating Temperature | - 14°F to 131°F(- 10° C to 55°C) |
Weight | 0. 4lb( 0. 18kg) |
Humidity | 0-95% non-condensing |
Dimensions | 6.53"Wx1. 57"Hx1. 53"D( 166x40x39mm) |
DESCRIPTION
The OD-22 passive infrared Sensor is specifically designed for
to-exit applications , Standard OD-22 include qualified motion
analysis. The OD-22 may be mounted toframe header,wall or ceiling.
Intended for indoor use only.
FEATURES
• Adjustable second time delay
• Micro-based signal processing
• High sensitivity
• Available in white or brown enclosure
2. DIMENSIONS
3. DESCRIPTION AND OPERATION
4. DETECTION PATTERN
5. INSTALLATION
Mounting Procedure
1. Select a mounting location over the center of the door or doors
to be covered. The target must walk
directly toward the detector.Mount the detector on the
ceiling,wall,or door frame.
2. Remove the front cover from the detector.
3. Route the wiring as necessary through the wiring entrance(refer
to the item 3 description and oper- ation).For surface wiring,use
the break out wiring entrance on the front cover(at the same end as
the wire entrance).
4. Loosely mount the back cover to the mounting sur- face using the
supplied mounting screws.
5. Aim the detector for the desired coverage.
6. Mount the front cover on the detector.
Long Range/Short Range Adjustment
The OD-22 can be set to detect individuals at either a long
rang(several steps from the door) or at short range (immediately in
front of the door).If the build- ing includes a lengthy approach to
the exit doorway and no other foot traffic in the area, choose the
long range setting.
Setup and Testing
1. Apply power to the unit.
2. Wait at least 3 min for the detector to settle.
3. Test the unit by walking directly throgh the coverage area,to-
ward the door.
4. Aim the detector up or down if necessary to obtain the proper
coverage.
5. Check that the relay latch time is sufficient Adjust if
necessary.
6. After confirming proper operation,replace the cover and walk
test one more time to ensure the coverage has not changed.
6. WIRING
Latch Time
DIP Switch 1,2,and 3 set the relay time.Latch time is adjustable
from 0.5 sec to 64 sec.It indicates the amount of time the relay
can remain active after the detector first sees motion.
>
Table1: Latch Time DIP Switch Settings |
Time(sec) | Switch 1 | Switch 2 | Switch 3 |
0.5(Default) | OFF | OFF | OFF |
1 | ON | OFF | OFF |
2 | OFF | ON | OFF |
4 | ON | ON | OFF |
8 | OFF | OFF | ON |
16 | ON | OFF | ON |
32 | OFF | ON | ON |
64 | ON | ON | ON |
>>
Table 2: LED Enable/Disable DIP Switch Settings |
Switch 4 | Function |
OFF | Disabled |
ON | Enabled (Default) |
Table 3:Relay Mode DIP Switch Settings |
Switch 5 | Function |
OFF | Fail Secure |
ON | Fail safe(Default) |
Table 4:Resettable/Non-resettable DIP Swithc Settings |
Switch 6 | Function |
OFF | Non-resettable |
ON | Resettable (Default) |
7. TROUBLE SHOOTING AND MAINTENANCE
>
TROUBLE | TROUBLE CAUSE | REMEDY |
Unit does not power up | No or low imput power. | Apply proper input voltage. |
Input power polarity reversed. | Correct wiring polarity. |
Alarm LED does not light | LED jumper is set to “LED OFF”. | Set LED jumper to “LED ENABLE” |
Incorrect sensor mounting height | Increase / decrease mounting height |
LED indicates light,no signal output | Incorrect wiring at output terminals | Correct wiring fault. |
Lightning damage | Replace sensor. |
Unit continues to operate after the input power has been
disconnected. | The wire to the “V-” power input was discon- nected, the “V+” is
still connected. | Disconnect wire from the “V+” power input. |
MAINTENANCE
INSPECTION: An inspection of this unit should be made periodically, consisting
of ,but not limited to all mounting, wiring
and the condition of the interior area and components.
CLEANING : Clean the plastic parts of this unit with a soft, clean, cloth
dampened with water.
TESTING : This unit should be tested rouinely for proper operation. At a
minimum, operation should be fully checked yearly.
Company Profile
AIN Technology (Shenzhen) Co., Ltd. is an international enterprise
which is exclusively designated and authorized by ALEPH Group to
sell ALEPH brand security products, door magnetic switches, and
Panther 4000, which is a wireless security systerm. AIN has set up
production bases and branches in China (Shenzhen, Zhuhai), Japan,
Europe, the United States and many other countries.
ALEPH brand alarm equipment, door magnetic switches and Baoping'an
smart home security products which are researched and developed by
AIN Technology have been all over the world. Especially the
independently researched and developed active infrared intrusion
detector which is the first in the world has been leading the
development and innovation of the infrared industry for China, even
the world.
AIN has a professional R&D team and high-quality management
personal, annually invests more than 15% of the operating income in
research and development and has two major product series of
“ALEPH” and AIN.
AIN has won the honor of a&s Top Ten International Brands for
ALEPH security products for many years. Furthermore, AIN is the
designate supplier of infrared detection products of Vanke Group.
Its products have been widely used in government agencies,
airports, nuclear power plants, factories, residential estates and
so on.
AIN has passed the following international quality system
certifications : ISO9001:2008, ISO14001: 2004 and
QC080000:2012; product certification: CCC, CQC, UL, CE, FCC, etc.