Electrical Metal Enclosed Switchgear , MNS Low Voltage Withdrawable Switchgear

Brand Name:HENGFENGYOU
Certification:ISO IEC CB COC KEMA SNI SABS CCC
Model Number:MNS
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:LC T/T
Contact Now

Add to Cart

Verified Supplier
Location: Qingdao Shandong China
Address: N0.506 Huicheng Road, Chengyang District, Qingdao City,China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details
Mns Switchgear of Low Voltage Withdrawable Electrical Metal-Enclosed Switchgear
Product Description

MNS series low voltage switch cabinet of Switzerland ABB Company,
and synthetically improved. The device is applicable to the system with AC 50Hz, rated working
voltage 660V and below, used as control device for various power generation, transmission, distribution
, power transfer and power consumption device. It is widely used in low voltage distribution system of
various mining enterprise, tall building and hotel, municipal construction etc. Besides the general land
use, after special disposal, it also can be used for marine petrol drill taken platform and nuclear power
station. The device accords with international standard IEC439-1 and national standard GB7251.1.

Work Environment

1. Ambient air temperature: -5℃+40℃and the average temperature should not exceed +35℃ in 24h.
2. Air condition: With clean air. Relative humidity should not exceed 50% at +40℃. Higher relative humidity i
s allowed at lower temperature. Ex. 90% at +20℃. But in view of the temperature change, it is possible that
moderate dews will produce casually.
3. Altitude above sea level should not exceed 2000M.
4. The device is suitable to the transportation and store with following temperature:-25℃ ~+55℃, in short
time (within 24h) it reaches +70℃. Under the limiting temperature, device should not suffer damage that
can[1]t recover, and it can works normally under normal conditions.


ItemData
Rated voltageto 660V
Ratd voltage impacte indurance8KV
Rated frequency50/60hz
Grounding systemTT,IT, TN-S,TN-C-S
Ratd voltage of auxiliary circuitAC380,220v/ DC220v
Maximum coil in and out broken circuit6300A
Pollution degree3
Rated current6300A
Horizontal busbar rated current4000A
Vertical busbar rated current2000A,1000A
Horizontal busbar ratd shorttime withstand current50/80KA
Horizontal busbar rated peak value withstand current105/176KA
Vertical busbar rated short time withstand current50KA
Vertical busbar rated peak value withstand current105KA


China Electrical Metal Enclosed Switchgear , MNS Low Voltage Withdrawable Switchgear supplier

Electrical Metal Enclosed Switchgear , MNS Low Voltage Withdrawable Switchgear

Inquiry Cart 0