Electric Furnace Transformer latest model

Brand Name:HENGFENGYOU
Certification:ISO IEC CB COC KEMA SNI SABS CCC
Model Number:S11
Minimum Order Quantity:1
Delivery Time:15 DAYS
Payment Terms:LC T/T
Contact Now

Add to Cart

Verified Supplier
Location: Qingdao Shandong China
Address: N0.506 Huicheng Road, Chengyang District, Qingdao City,China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Electrical oven transformer



Product description

The electric furnace transformer produced by our company absorbs the advanced technology and process of the same industry all over the world. The iron core adopts high magnetic conductivity silicon steel sheet and five-stage step stacking mode to reduce no-load loss and noise. High quality oxygen free copper conductor is used for electromagnetic wire. With special structure, the transformer has many advantages, such as strong overload capacity, high anti-short circuit ability and so on, which makes the technical performance of the product at the domestic advanced level.


Structure features


1. Iron core

The core of the shell furnace transformer is a frame structure with full oblique joint. The iron core has narrow width, good heat dissipation conditions and simple structure.


2. Winding

The winding of the shell furnace transformer is a rectangle with the same shape as the section of the core column. The low-voltage winding is made of a whole copper plate, with good heat dissipation conditions, and the outlet is of welded structure; the high-voltage winding is of pie structure. The winding arrangement shall be staggered. The high voltage line and low voltage line in each group should have equal magnetic potential, and their radial dimensions should be basically equal. Theoretically, the low-voltage line segment is placed at both ends because of its small insulation distance to the core. However, in order to make the short-circuit impedance of the transformer smaller, it needs more than one magnetic flux leakage group to meet the requirements, and the number of magnetic flux leakage groups will be limited when the low-voltage line segments are placed at both ends, so sometimes the high-voltage line segments are placed at both ends. In the process of voltage regulation, in order to make the line configuration symmetrical and ensure the magnetic potential balance, multi-channel parallel connection is usually used in the voltage regulation line, so as to ensure that the impedance of each magnetic leakage group is equal and the current of each low-voltage line section is equal.


3 Cooling mode

The shell type electric furnace transformer generally adopts forced oil-oriented circulation, forced water cooling or forced oil-oriented circulation, forced air cooling. As the shell type transformer can easily place a partition between the oil tank and the body, the cooled transformer oil is forced to flow through the line cake, the oil flow is uniform, the temperature difference of each part is small, the heat dissipation effect is good, the hottest point temperature can be reduced by about 5°C, and the additional overload capacity of the transformer can be increased.


4. Oil tank

Because the winding of the shell transformer is completely shielded by the iron core, the possibility of damage due to the external force is small, so the oil tank of suitable shape can be adopted according to the shape of the body, so that the size and weight of the transformer are greatly reduced.


Technical data


Specification and parameter table of electric furnace transformer of non excitation voltage regulation


Rated capacity

kVA

Primary voltage

kV

Secondary voltage

kV

Rated secondary current

A

Voltage regulating modeVector GroupShort-circuit voltage %Series reactor
Large impedanceSmall impedanceCharged reactor

rated capacity

kVAR

reactance drop

%

630

6

6.3

10

10.5

11


200

170

116

98

1819non excitation voltage regulation

D(Y)

d0(11)

24-2610- 11(8-9)12019
8002309150
10002887190
1250

210

180

121

104

343722-249- 1020016
16004399260
20005499320
2500

220

190

127

110

656121-238-928011.2
3150826719-217- 8350
4000

240

210

139

121

96233408.5
500012028430
6300

260

240

210

139

139903605.7
800017765(7-8)460

Specification and parameter table of on-load voltage regulating electric furnace transformer


Rated capacity

(kVA)

Primary voltage

kV

Secondary voltage VLevel voltage

Rated secondary current

A

Voltage regulation modeRegulating seriesVector Group

Short-circuit

impedance

(%)

constant powercontinuous current
10000

35

38.5

280-240240-1001024056Split phase on load voltage regulation (maximum allowable level difference of each phase is 3 levels)Class 19 (first 5 constant power output, last 15 constant current output)

Dd0;

Yd11

YN d11

7~8
12500314-270270- 1161126729
16000353- 305305- 1371230287
20000

35

38.5

110

121

392-340340-1581333962

35kV

Dd0;

Yd11;

YN dl1

110 kV

YN d11

35kV

6-7

110 kV

7.5~ 8.5

25000436- 380380-1841437984
31500489-425425-2011642792
40000547-475475-2231848619
50000610- 530530-2502054467
63000673-585585-2772562176
80000760-660660- 3102869982

·Service conditions


1. Altitude: < 1000m.

2. Ambient temperature: - 25 ℃ - + 40 ℃.

3. Relative humidity of air: 90% (+ 25 ℃).

4. Device type: outdoor type.

5. Installation site: no corrosive gas, no obvious dirt and other areas.

6. It is used for steelmaking, smelting of non-ferrous metals, withdrawal of various ferroalloys, silicon compounds, withdrawal of pure silicon, etc.


Workshop



If any interest , pls feel free to contact us:


China Electric Furnace Transformer  latest  model supplier

Electric Furnace Transformer latest model

Inquiry Cart 0