Low Voltage Switchgear Cabinet / High-Tension Switch Cabinet / Generator Integrated Protection Panel Switchgear
1.GCS type LV low voltage distribution cabinet is suitable for three-phase AC 50HZ, max voltage 380V, rated current to 3150Apower distribution system , it is widely used in power plants, substations, industrial and mining enterprises etc energy consumer and using for power, lighting and distribution equipment for electrical energy conversion, distribution and control purposes.
2.Protection grade is IP30. IP20-IP40 could be optional acc to the requirements of service condition.
3.Good appearance. easy assembly and disassembly.
The device is suitable for power conversion, distribution and
control of power, power distribution and motor control centers,
capacitor compensation, etc. of power plants, substations,
petrochemical departments, factories and mines, high-rise buildings
and other low-voltage power distribution systems.
When used in low-voltage control centers and motor control centers
in large-scale power plants, large-scale petrochemical industries,
etc., it can meet the special needs of computer interfaces. The
device is developed according to the requirements of the
supervisors of the Ministry of Electric Power, the majority of
power users and the design department, in order to meet the needs
of the evolving power market capacity expansion, computer
interface, centralized power control, convenient installation and
maintenance, and shortening the processing time of accidents. The
device has the characteristics of good dynamic thermal stability,
flexible electrical scheme, convenient combination, strong
seriality, novel structure and high protection level.
The device complies with IEC439-1, GB7251, ZBK36001 and other
standards.
Environmental conditions
When working normally,the detailed climate environment should be referenced to provisions of IEC60439-1,EN60439,Part 500 in VDE0660.And the ambient humidity is 50% in 40℃.
The conditions of the indoor installation of the switchgear shall
meet the requirements of the corresponding standards. In the case
of condensation, ventilation or heating lamp will be used to
prevent condensation.
If the switchgear is installed in the areas whose altitude is above
2000 meters, the equipment should be operated with reduced capacity
accordingly.
Item | parameter | ||
Rated insulation voltage | |||
Rated working voltage | Primary loop | AC 660 (1000) V | |
AC 380 (660) V | |||
Auxiliary circuit | AC 380, 220, 24 V | ||
DC 220, 110 V | |||
Rated frequency | 50 (60) Hz | ||
Rated current of horizontal bus | < 4000 A | ||
Rated current of vertical bus | 1000 A | ||
Rated peak tolerant current | 105 (176) KA | ||
Rated short-term tolerant current (1s) | 50 (80) KA | ||
Power frequency testing voltage | Main loop to the ground | 2500 V/min | |
Auxiliary circuit to the ground | 2000 V/s | ||
Protection grade | IP3x |
Note: Due to continuous product improvement, the dimensions provided in this sample are for reference only. If necessary, our company can design and produce according to user requirements. Please contact the company in time.
Company introduction
Qingdao HengFengYou Electrical Engineering Co. LTD., aka HFY
Electrical Engineering, is a Chinese leading manufacturer and
supplier in electricity transmission and distribution industry.
With 30 years of competition and development in China, by now HFY
Electrical Engineering has 6 wholly-owned subsidiaries, 50 senior
technicians, 350 employees, established sales network and customer
service team. From research and development, manufacturing to the
final project engineering, HFY provides better solution to clients
than others.
Our main market covers medium voltage, high voltage and ultra-high
voltage power distribution.
1. Indoor altitude above sea level: Maximum installation altitude: 2000m
2. Ambient air temperature: -5℃~+40℃ and the average temperature should not
exceed +35℃ in 24h
3. Relative humidity should not exceed 50% at max temperature +40℃. Higher
relative humidity is allowed at lower temperature. Ex. 90% at +20℃. But in view of
the temperature change, it is possible that moderate dews will produce casually.
4. No fire, explosion danger, serious pollution, chemical corrosion and severe vibration
5. Installation gradient not exceed 5°
6. This product is suitable for the following temperature transportation storage: -25℃ ~+55℃ 24h, in a short period of time (no more than 24hours) not more than+70℃.