Add to Cart
Scb13 Dry Type Transformer, Power Transformer Manufacturer, Dry Type Electrical Transformer
S13-M.RL-80-1600/10-type full - sealed oil-immersed transformers for AC 50Hz, rated working voltage
of 10kV and below the power system, as petroleum, metallurgy,
chemical, textile, light industry and other corporate and
relatively dust Great place for distribution transformers.
Features
1 Hermetically sealed or breathing tank
For Distribution Transformers, the default construction is the
hermetically sealed non-rigid tank completely filled. Air cushion
in used with rigid tanks. The variation of oil volume, due to its
temperature variation, is absorbed in the flexible fins of the
corrugated panels, and in the air cushion when applicable.
Breathing tank with conservator is also a possible configuration.
2. Tank types
The transformer tank is usually of a non rigid structure with
corrugated panels, designed to withstand the mechanical stresses,
absorb the oil expansion, and meet the thermal evacuation
constraints.
For power rating above 3150kVA, the tank is usually designed with
rigid structure, cooling radiators and conservator.
3. Cover
For distribution transformers, covers are made of steel plates with
bended edges, thus improving the esthetical aspect and reinforcing
the cover which is especially important when untanking the unit.
Accessories are mounted on the cover through adequate connectors.
Multifunction holes can be provided to receive different type of
accessories.
For example, on the same hole, alternatively a DMCR or a pressure
relief valve or a thermometer can be mounted.
4. Magnetic circuit
The magnetic circuit is of the three legs construction, Step lap.or
GT.
It is made out of a cold rolled, grain oriented silicon steel
strips, each strip (0.23, 0.27or 0.30mm thick) being insulated from
both sides by Carlite.
5. Winding coils
Both the primary and secondary windings are made of copper or
aluminum.
The primary voltage is directly wound on the secondary voltage
winding, with insulating barriers and cooling channels between the
two windings.
Secondary voltage coils are of rectangular wires or foil
conductors. Primary voltage coils are of round enamelled wires, or
rectangular paper insulated wires for high power ratings, or round
paper insulated wires.
Adequate channels for oil circulation are integrated in the
windings to provide an efficient cooling and limit the hot spot
temperature.
KVA | Voltage | VECTOR GROUP | LOSSES | No-Load Current | Weight(kg) | Overall dimension (mm) | |||||
H.V(KV) | L.V(KV) | No-Load Loss | Load Loss | Oil Weight | Total Weight | L | W | H | |||
20 | 6 6.3 10 10.5 11 13.2 | 380 400 415 433 | YynO Dyn11 Yzn11 | 90 | 530 | 2.3 | 55 | 230 | 720 | 440 | 855 |
30 | 100 | 600 | 2.1 | 75 | 305 | 750 | 500 | 990 | |||
50 | 130 | 870 | 2.0 | 80 | 405 | 800 | 480 | 1030 | |||
63 | 150 | 1040 | 1.9 | 95 | 455 | 830 | 615 | 1060 | |||
80 | 180 | 1250 | 1.9 | 105 | 510 | 840 | 580 | 1115 | |||
100 | 200 | 1500 | 1.8 | 120 | 530 | 890 | 645 | 1145 | |||
125 | 240 | 1800 | 1.7 | 130 | 670 | 910 | 600 | 1185 | |||
160 | 280 | 2200 | 1.6 | 140 | 810 | 910 | 700 | 1280 | |||
200 | 340 | 2600 | 1.5 | 160 | 890 | 1000 | 760 | 1240 | |||
250 | 400 | 3050 | 1.4 | 175 | 1020 | 1285 | 730 | 1290 | |||
315 | 480 | 3650 | 1.4 | 185 | 1170 | 1280 | 740 | 1385 | |||
400 | 570 | 4300 | 1.3 | 215 | 1410 | 1310 | 750 | 1432 | |||
500 | 680 | 5100 | 1.2 | 260 | 1645 | 1365 | 765 | 1510 | |||
630 | 810 | 6200 | 1.1 | 310 | 2070 | 1485 | 815 | 1615 | |||
800 | 980 | 7500 | 1.0 | 370 | 2445 | 1640 | 930 | 1590 | |||
1000 | 1150 | 10300 | 1.0 | 425 | 2800 | 1860 | 1120 | 1630 | |||
1250 | 1360 | 12000 | 0.9 | 480 | 3320 | 1860 | 1120 | 1830 | |||
1600 | 1640 | 14500 | 0.8 | 550 | 4175 | 1975 | 1175 | 1900 |
Typical test values and performances are performed in the painting
lab on steel plates during the whole painting process in order to
confirm the following:
• Minimum paint thickness film (ISO 2808): 70µm
• Specular gloss factor at 60 Deg (ISO 2813): 90 +/- 5%
• Falling weight test (ISO 6272): 1Kg/050cm
• Erichsen cupping test (ISO 1520): 08mm
• Scratch test (Adhesion ISO 2409): 0
• Bend Test (cylindrical mandrel ISO 1519): 3,0mm
• Salt spray (Fog) test (ISO 7253): Over 1000 Hours