Add to Cart
CQ series resistance to corrosion magnetic drive pump for transfer
acid/alkali/oil/leaky/inflammable expensive liquid
CQ series resistance to corrosion magnetic drive pump for transfer
acid/alkali/oil/leaky/inflammable expensive liquid (referred to as magnetic pump) is a new product that uses the
working principle of permanent magnet coupling for centrifugal
pump. It has reasonable design, advanced technology, full sealing,
no leakage and corrosion resistance. Its performance has reached
abroad. The advanced level of similar products. The magnetic pump
replaces the dynamic seal with a static seal, so that the
over-current component of the pump is completely sealed, completely
solving the disadvantages of running, escaping and dripping which
cannot be avoided by the mechanical seal of other pumps. The
magnetic pump is made of corrosion-resistant and high-strength
engineering plastic. Steel jade ceramics and stainless steel are
used as manufacturing materials, so it has good corrosion
resistance and can protect the transport medium from contamination.
The magnetic pump has compact structure, beautiful appearance,
small volume, low noise, reliable operation and convenient use and
maintenance. Can be widely used in chemical, pharmaceutical,
petroleum, electroplating, food, film photofinishing, scientific
research institutions, defense industry and other units to pump
acid, lye, oil, rare precious liquids, venom, volatile liquids, and
circulating water equipment, Filter kit. Especially for the pumping
of leaky, flammable and explosive liquids, it is more ideal to use
this pump.
CQ series resistance to corrosion magnetic drive pump for transfer
acid/alkali/oil/leaky/inflammable expensive liquid installation and
use
1. The magnetic pump should be installed horizontally and should
not be erected. The plastic pump body must not bear the weight of
the pipeline. For the special requirements of vertical
installation, the motor must face upwards.
2. When the suction liquid level is higher than the pump shaft
line, open the suction pipe valve before starting. If the suction
liquid level is lower than the pump shaft line, the pipe should be
equipped with a bottom valve.
3. The pump should be inspected before use. The motor blades should
be flexible to rotate, no jamming, no abnormal sound, and the
fasteners should be fastened.
4. Check if the motor rotation direction is consistent with the
magnetic pump steering mark.
5. After the motor starts, slowly open the discharge valve. After
the pump enters the normal working state, adjust the discharge
valve to the required opening degree.
6. Before the pump stops working, close the discharge valve and
close the suction pipe valve.
CQ series resistance to corrosion magnetic drive pump for transfer
acid/alkali/oil/leaky/inflammable expensive liquid use precautions
1. Since the cooling and lubrication of the magnetic pump bearing
is based on the medium to be transported, it is absolutely
forbidden to perform the air-to-air transfer, and at the same time
avoid the time-and-load operation caused by the power failure after
the start of the work.
2. If the solid medium is contained in the medium to be
transported, a filter should be added to the pump inlet: if it
contains ferromagnetic particles, a magnetic filter is required.
3. The ambient temperature of the pump should be less than 40 °C
during use, and the temperature rise of the motor should not exceed
75 °C.
4. The medium to be transported and its temperature should be
within the allowable range of the pump (see attached table for
details). The working temperature of the engineering plastic pump
is <60 °C, the use temperature of the metal pump is <100 °C,
the suction pressure is no more than 0.2mpa, the working pressure
is 1.6mpa, the density is not more than 1600kg/m3, and the particle
size is not more than 30×10-6m2/s. A liquid that does not contain
hard particles and fibers.
5. For the medium which is easy to precipitate and crystallize, the
medium should be cleaned in time after use, and the liquid in the
pump should be drained. 6. After the magnetic pump is operated for
500 hours, the wear of the bearing and the end moving ring should
be dismantled. If the clearance between the bearing and the bushing
is greater than 0.5~1mm and the impeller axially moves 1.5~2mm, the
bearing and axial movement should be replaced. ring.
PH Value of slurry: 2.5-13 | Slurry temperature ≤ 65ºC | X type frame,space saving |
Large capacity | High head | High efficiency |
Wear resistance | Corrosion resistance | Energy saving |
Wide flow range | Stable performance | Heavy duty |
Little noise | Low vibration | Long service life |
Interchangeable parts | Reliable operation | High chrome alloy material |
Oil lubrication | Clockwise from drive end | Intergrating mechanical seal |
CQ series resistance to corrosion magnetic drive pump for transfer acid/alkali/oil/leaky/inflammable expensive liquid Performance data
Model | Inlet | Outlet | Head | Capacity | Power | Speed | Voltage | Stainless steel |
(mm) | (mm) | (m) | (L/min) | (KW) | (r/min) | (Phase) | ||
14CQ-5 | 14 | 10 | 5 | 20 | 0.18 | 2800 | 1ph/3ph | |
16CQ-8 | 16 | 12 | 8 | 30 | 0.18 | 2800 | 1ph/3ph | |
20CQ-12 | 20 | 12 | 12 | 50 | 0.37 | 2800 | 1ph/3ph | |
25CQ-15 | 25 | 20 | 15 | 110 | 1.1 | 2800 | 3phase | |
32CQ-15 | 32 | 25 | 15 | 110 | 1.1 | 2800 | 3phase | |
32CQ-25 | 32 | 25 | 25 | 90 | 1.1 | 2800 | 3phase | |
40CQ-20 | 40 | 32 | 20 | 180 | 2.2 | 2800 | 3phase | |
40CQ-32 | 40 | 32 | 32 | 200 | 4 | 2800 | 3phase | |
50CQ-25 | 50 | 40 | 25 | 240 | 4 | 2800 | 3phase | |
50CQ-32 | 50 | 40 | 32 | 220 | 4 | 2800 | 3phase | |
50CQ-50 | 50 | 32 | 50 | 130 | 5.5 | 2800 | 3phase | |
65CQ-25 | 65 | 50 | 25 | 280 | 5.5 | 2800 | 3phase | |
65CQ-32 | 65 | 50 | 32 | 450 | 5.5/7.5 | 2800 | 3phase | |
80CQ-32 | 80 | 65 | 32 | 850 | 11 | 2800 | 3phase | |
80CQ-50 | 80 | 65 | 50 | 850 | 15 | 2800 | 3phase | |
100CQ-35 | 100 | 80 | 35 | 1000 | 15 | 2800 | 3phase | |
100CQ-50 | 100 | 80 | 50 | 1000 | 18.5 | 2800 | 3phase | |
125CQ-32 | 125 | 100 | 32 | 1700 | 22 | 2800 | 3phase | |
125CQ-32 | 125 | 100 | 32 | 2500 | 30 | 1450 | 3phase | |
150CQ-25 | 150 | 125 | 25 | 3350 | 30 | 1450 | 3phase |