IEC 61000-3-2 EMC Test Equipment Harmonic Current / Voltage Fluctuations And Flicker EMI Test

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN669
Minimum Order Quantity:1
Delivery Time:60 Days
Payment Terms:L/C, , T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

IEC 61000-3-2 Harmonic Current, Voltage Fluctuations and Flicker EMI Test System


Standards & Clauses:


IEC 61000-3-2 / GB 17625.1: Harmonic Current Limit Issued by Low-Voltage Electrical and Electronic Equipment (Equipment Input Current ≤16A per Phase)
IEC 61000-3-3 / GB 17625.2: Limits of voltage fluctuations and flicker in low-voltage power supply systems for equipment rated up to 16A


Samples and Restrictions:


Electronic products, lighting equipment


Application:


Harmonic current testing primarily measures the harmonics injected into the grid while the EUT is operating. Voltage fluctuations and flicker mainly measure the voltage changes in grid caused by EUT.


Test Principle:


Due to extensive use of switching power supplies in electronic products, while improving power efficiency, a large amount of harmonic current is injected into the power grid due to non-linear power conversion, which not only interferes with other devices in the same power grid but also causes the neutral Current overload, affecting transmission capacity. In addition, the phase control of the power supply can also cause changes in the rms current of the power grid, causing the rms voltage on the load side to fluctuate, causing the lights of the lighting to flicker.


Structure:


Main test equipment: pure power, harmonic scintillation analyzer, EMC test software
Test environment: general laboratory


Use Environment​:


Power supply: 220V ± 10%, 50 / 60Hz

Ambient temperature: 5 °C ~ +40 °C, there should be no high concentration of dust, corrosive gas, flammable and explosive objects


Technical Parameters:


Main Test EquipmentPure power source, harmonic scintillation analyzer, EMC test software, etc.