Add to Cart
5 in 1 Desktop Electrical Safety Compliance Tester
Standards & Clauses:
IEC60884-1:2013 “Plugs and socket-outlets for household and similar
purposes- Part1: General requirements”
IEC60335-1:2016 “Household and similar electrical
appliances-Safety-Part1: General requirements”
IEC60950-1:2013 “Information technology equipment-Safety-Part1:
General requirements”
IEC60065:2014 “Audio, video and similar electronic apparatus-Safety
requirements”
Samples and Restrictions:
Household appliances, electrical accessories, lamps, etc.
Application:
Various types of home appliance manufacturers, as well as
institutions that conduct home appliance safety testing and
certification, research institutes
Test Contents:
AC withstand voltage, insulation resistance, grounding resistance,
leakage current, power test
Features:
■ 5.7” Blue background LCD display, data display is intuitive and
clear
■ Meet standard requirements of CCC,IEC,EN,VDE,BS,GS,UL, etc.
■ Industrial computer system is optional, which supports to add
barcode scanner to achieve automatic control and data entry, build
production data management platform, and can be integrated into
production management system
■ Variable frequency power supply is optional, which supports to
form an automatic test system, realize automatic adjustment of test
power supply output, without manual intervention, to ensure
accurate test results
■ 15 sets memory of test condition, 8 test steps in each group,
specifications of each group can be set separately, easy for query
■ Fast speed: The control core of the test instrument adopts ARM
high-speed processor, the data processing is comprehensive and fast
■ Withstand voltage can be ramped up and ramp downed, has upper and
lower limit alarm functions
■ Adopts digital closed loop feedback control, and fully automatic
pressure regulation mode, the output voltage/current is
automatically corrected and is not affected by external grid
fluctuations, ensuring the accuracy of the test
■The grounding resistance test can select voltage mode or resistance
mode, to meet different national/industry standards
■ Built-in leakage current body network as per IEC 60990 figure 4,
can customize other body networks - optional
■ Standard PLC remote control, RS232 and alarm light interfaces
Technical Parameters:
AC Withstand Voltage Test | |
Output voltage setting range / accuracy | AC 200~5000V, ± (3% × setting + 5 words) |
Breakdown current measurement range / accuracy | 0.10~25.00mA, ± (3% × reading + 5 words) |
Breakdown current preset alarm range | Upper limit: 0.10~25.00mA; lower limit: 0.00~5.00mA |
Test time range / resolution | 1~300s, 1s/step |
Insulation Resistance Test | |
Output voltage setting range / accuracy | DC 500/1000V, ± (3% × reading + 5 words) |
Insulation resistance measurement range / accuracy | 1~2000MΩ |
Insulation resistance alarm setting range | Upper limit: 0 to 2000 MΩ |
Test time range / resolution | 1~300s, 1s/step |
Grounding Resistance Test | |
Ground current output range / accuracy | AC 5.0~30.0A, ± (3%×setting+5 words) |
Ground resistance measurement range / accuracy | 10.0 to 600 mΩ, ± (3% × reading+ 5 words) |
Grounding resistance alarm setting range | Upper limit: |
Test time range / resolution | 1~60s, 1s/step |
Leakage Current Test | |
Output voltage | 1.06 times rated voltage |
Leakage type setting | Dynamic leakage, static leakage. Default leakage current body network as per IEC 60990 figure 4 built-in, other body network can be customized. If have special requirements, pls specific which body network you prefer, cost may be different |
Output voltage measurement range / accuracy | AC 50 ~ 280V, ± (3% ×reading + 2 words) |
Leakage current measurement range / accuracy | 0.05~20.00mA, ± (3% ×reading + 10uA) |
Leakage current setting alarm range | Upper limit: 0.05~20.00mA |
Test time range | 1~300s, 1s/step |
Power Test | |
Output voltage | 1.0 times rated voltage |
Output voltage measurement range / accuracy | AC 50~280V, ± (0.5% × reading + 2 words) |
Output current measurement range / accuracy | AC 0.2~30.00A, ± (0.5% × reading + 2 words) |
Active power measurement range / accuracy | 30~6000W, ± (0.5% × reading + 5 words) |
Power setting alarm range | Upper limit: 3~6000W |
Test time range / resolution | 1~300s, 1s/step |
General | |
Interfaces | RS232, alarm light interface |
Standard Accessories | Power cord * 1, 30A test clamp * 1, test box * 1, test power input line * 1, fuse * 1 |
Optional Accessories | Alarm light, foot switch |
Equipment Dimensions (MM) | W 435W * H 150H* D 550D |
Connection with Sample