Programmable Multi-standard Leakage Current Tester 1000VA 2000VA LCD Display

Standards & Clauses:


The tester conforms to IEC 60601-1: 2005+A1:2012, IEC 60950-1: 2005+A1:2009+A2:2013, IEC 60065: 2014, IEC 61010-1: 2010+A1:2016, IEC 60990:2016 and etc.


Samples and Restrictions:


Household appliances, electrical accessories, lamps, medical appliances, information and communication equipment,etc.


Application:


Various types of laboratories, home appliance manufacturers, as well as institutions that conduct home appliance safety testing and certification, research institutes, etc.


Test Contents:


This tester can simulate following 6 types of MD networks:


MD-A compliant to : IEC 60990

IEC 61010-1


MD-B compliant to : IEC 60990

IEC 61010-1

IEC 60335-1

IEC 60950-1

IEC 60665

IEC 60598-1


MD-C compliant to : IEC 60990

IEC 60598-1


MD-D compliant to : IEC 61010-1


MD-E compliant to : IEC 60950-1

IEC 61010-1


MD-F compliant to : IEC 60598-1


Technical Parameters:


ModelSN2212L-1KSN2212L-2KSN2212L-3KSN2212L-4K
Input characteristicsSingle-phase 50Hz, 60Hz 110 / 220Vac ± 10%
Output Capacity1000VA2000VA3000VA4000VA
Output voltage setting30.0V ~300.0V, Resolution: 0.1V / Step
Current upper limit setting range0.1μA ~20.00mA
Current lower limit setting range0.0μA~20.00mA
Wave detection methodDC/AC/AC+DC/AC Peak
Voltmeter

(0.0-250.0) V

Resolution: 0.1 V

Accuracy: ± (2% of reading + 2V)

(0.0-300.0) V

Resolution: 0.1 V

Accuracy: ± (2% of reading + 2V)

Ammeter

0.0uA-20.00mA

Resolution: 0.1uA for 200.0μA range, 0.001mA for 2mA range, 0.01mA for 20mA range, Accuracy: ± (2% of reading + 2 words)

Test time

(0.1-999.9) seconds,

0 = continuous

(0.0,0.3~999.9)s,

0 = continuous

Intervals

(0.1-999.9) seconds,

0 = Test time is over, the tester stops automatically

(0.0-999.9) seconds,

0 = Interval time off

Rise time

(0.1-999.9) seconds,

0 = rise time off

(0.0-999.9) seconds,

0 = voltage rise time off