Add to Cart
IEC60309-1 Clause 20 Vehicle Connector and Plug Breaking Capacity Test Machine
Product Information:
The Vehicle Connector and Plug Breaking Capacity test machine conforms to the standard requirements of IEC60309-1 clause 20 and clause 21, IEC62196-1 clause 7.11 and clause 7.12 and etc.
It is used to verify whether electrical accessories such as electric vehicle charging interfaces, industrial plugs, socket-outlets and couplers can withstand the mechanical, electrical and thermal stresses that occurred during normal operation without excessive wear or other harmful effects.
Technical Parameters:
Applied standard | IEC IEC60309-1 |
Applied clause | Clause 20 and 21 |
Test station | Single |
Control method | PLC intelligent integrated control, with color humanized touch screen |
Drive mode | Servo motor drive |
Sample clamping method | Mechanical clamping, the position of clamping point can be adjustable along the 3-axis fixture |
Linear stroke | 0-100mm, can be preset (the spacing between test plug and test socket≥ 50mm) |
Conduction time | 0-99.9s, can be preset (electrical contact should be maintained no more than 4s, no less than 2s) |
Speed of Insertion and Separation | 0-0.85m/s can be preset, default(0.8±0.1)m/s) |
Test frequency | 0-10 cycles/min, can be preset (3.75cycles/min=7.5 stoke/min) |
Test cycles | 0~999999 cycles, can be preset |
Load power | External, providing standard required voltage, current and power factor, the load cabinet is optional |
Optional load cabinet | Note: only with AC load cabinet, 0-70A, voltage 0-300V |
Test contents | Appliance coupler/charging interface breaking capacity test Appliance coupler / charging interface normal operating life test |
Detection function | An open circuit alarm can be realized during testing under load, and the cycles can be recorded real in time. |
Safety protection | Ground protection, short circuit protection |