IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions
Product Information For Multimeter Electrical Safety Tester:
This multitester electrical safety tester Conforms to IEC 60598-1 clause 8.2.3, clause10.2.1, clause 10.2.2, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 13, Clause 16, Clause 27 and etc. It integrates 6 functions of hi-pot, insulation, grounding, leakage, power, low-voltage start testing.
Features For Multimeter Electrical Safety Tester:
■Meet CCC, IEC, EN, VDE, BS, GS, UL and other electrical safety standards
■Unlimited storage of test conditions and test results
■Data can be copied via USB
■Fast speed: ARM high-speed processor is used as the control core of the test instrument, and data processing is comprehensive and fast
■High accuracy: safety test accuracy up to 1.5%
■Ramp rise and down of voltage withstand can be set, and with upper and lower limit alarm function
■Digital closed-loop feedback control mode, fully automatic voltage regulation mode, output voltage / current is automatically corrected, and it is not affected by external power grid fluctuations to ensure the accuracy of the test
■Two judgment modes can be chosen for ground resistance test: voltage and resistance, to meet the requirements of different national / industry standards
■Built-in one human body network fora leakage current test, which can be customized to any human body network-optional function
Technical Parameters For Multimeter Electrical Safety Tester:
Model | Functions | Capacity | Accuracy | |
SN2212 | ACW/IR/GB/LC/PWR/STR | Built-in Frequency Power Supply, 5KVA | 1.5% | |
AC withstand voltage | ||||
Output voltage setting range | AC 200~5000V | |||
Output voltage accuracy | ±(1.5%×setting+5words) | |||
Output voltage setting step | 1V | |||
Output frequency | 50/60Hz | |||
Output waveform | Sine wave | |||
Distortion of output waveform | Less than 2% (at purely resistive load) | |||
Output waveform adjustment rate | Less than(2%* setting +5V) | |||
Output capacity | 500VA | |||
Output voltage ramp-down time setting range | 0~300s | |||
Set step | 0.1s | |||
Breakdown current measurement range | 0.10~99.99mA | |||
Breakdown current test accuracy | ±(1.5%×reading+5words) | |||
Breakdown current preset upper limit | 0.10~99.99mA | |||
Breakdown current preset lower limit | 0.00~5.00mA | |||
Breakdown current preset step | 0.01mA/step | |||
Test time setting range | 1~300s | |||
Test time setting step | 1s/step | |||
Arc detection | 1~9 Level (level 9 is the highest sensitivity) | |||
Insulation resistance | ||||
Output voltage setting range | DC 200~1000V | |||
Output voltage accuracy | ± (1.5%×reading+5 words) | |||
Output voltage setting step | 1V | |||
Output capacity | 60VA | |||
Output voltage ramp-down time setting range | 0~300s | |||
Set step | 0.1s | |||
Insulation resistance measurement range / accuracy | 1~2000 MΩ ≤100 MΩ:±(5%×displaying+3words) >100 MΩ:±(8%×displaying+8words) | |||
Insulation resistance alarm setting range | Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ | |||
Test time range, resolution | 1~300s 1s/step | |||
Ground resistance | ||||
Ground current output range / accuracy | AC 5.0~30.0A | |||
Ground current accuracy | ±(1.5%×setting+0.2A) | |||
Ground resistance measurement range | 10.0~600mΩ | |||
Ground resistance measurement accuracy | ±(1.5%×displaying+3mΩ) | |||
Ground resistance alarm setting range | Upper limit: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ; lower limit:0.0~100mΩ | |||
Ground resistance setting step | 1mΩ | |||
Test time range | 1~300s | |||
Test time step | 1s/step | |||
Leakage current | ||||
The output voltage | 1.06 times rated voltage provided by the built-in variable frequency power supply | |||
Leak type setting | Dynamic leakage, static leakage, built-in one leakage current human body network, any human body network can be customized | |||
Output voltage measurement range | AC 50~280V | |||
Output voltage frequency | AC 45~65Hz | |||
Output voltage accuracy | ±(0.5%×displaying+2words) | |||
Leakage current measurement range | 0.05~20.00mA | |||
Leakage current measurement accuracy | ± (1.5%× displaying +10uA) | |||
Leakage current setting alarm range | Upper limit: 0.05 ~ 20.00mA; lower limit: 0.01 ~ 5.00mA | |||
Leakage current setting step | 0.01mA | |||
Test time range | 1~300s 1s/step | |||
Power | ||||
Output voltage | 1.0 times rated voltage, provided by built-in variable frequency power supply | |||
Output voltage measurement range / accuracy | AC 50~280V ±(0.5%×displaying+2 words) | |||
Output current measurement range / accuracy | AC 0.20~30.00A ±(0.5%× displaying +2 words ) | |||
Active power measurement range / accuracy | 30~6000W ±(0.5%× displaying +5 words ) | |||
Power setting alarm range | Upper limit: 3 ~ 6000W , Lower limit: 0 ~ 6000W | |||
Test time range / resolution | 1~300s 1s/step | |||
Low voltage start | ||||
Output voltage | 0.85 times rated voltage provided by the built-in variable frequency power supply | |||
Output voltage measurement range / accuracy | AC 50~280V ±(0.5%× displaying +2words) | |||
Starting current measurement range / accuracy | AC 0.20~30.00A ±(0.5%× displaying +2 words ) | |||
Current setting alarm range | Upper limit:0.20~30.00A Lower limit: 0.00~25.00A | |||
Test time range | 1~300s 1s/step | |||
Communication Interface | 232 485 can Bus TCP / IP interface | |||
External control method | PLC interface, switch signal | |||
System appearance | Size:600W*1840H*600Dmm Height with pulley, alarm light | |||
System standard accessories | Power cord × 1, foot switch × 1, 30A test clamp × 1, test box × 1, power input line × 1, fuse tube × 1 |