CISPR16-1-1 Gigahertz Transverse Electro Magnetic Cell EMI Test System

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN6018-4M
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

CISPR16-1-1 Gigahertz Transverse Electro Magnetic Cell EMI Test System


Product Overview For EMI Test System:


1. EMI Conducted Magnetic Disturbance Test System

This system mainly measures the interference caused by the equipment under test (EUT) to the surrounding environment through the power line (conducted disturbance) or in the form of space radiation (electric field radiation disturbance) under normal working conditions. The system is mainly composed of EMI test receiver, artificial power network (LISN), radiation receiving antenna, and special test software, which fully complies with the requirements of CISPR, FCC, MITL, GB and other relevant standards.



2. Radiated Emission Testing System

Using GTEM (Gigahertz Transverse Electromagnetic Wave) for electromagnetic compatibility testing is a new measurement technology developed in the field of international electromagnetic compatibility in recent years. Due to the broadband characteristics of GTEM (from direct current to microwave), low cost (only a few percent of the cost of the anechoic chamber), it can be used for both electromagnetic radiation test (EMI test) and electromagnetic radiation sensitivity test (EMS test sometimes also known as immunity test). Moreover, the instrument used (compared to the experiment in the anechoic chamber) has the characteristics of simple configuration, low cost and quick and automatic testing, so it has attracted more and more attention from international and domestic relevant people. Among them, especially for the testing of small equipment, the measurement solution of the GTEM cell is the test solution with the best performance-price ratio.


Product Features For EMI Test System:


1. PMM 7010 is an all-digital integrated EMI measurement receiver developed to meet the needs of product designers to perform massive EMC evaluation and measurement in the trial production stage.

2. Disturbance measurement in compliance with certification standards

3. For the civil standard test, the PMM 7010 weighted detector not only includes CISPR-Avarage and RMS-Avarage specified in CISPR16-1-1, but also has a unique APD detector (amplitude probability distribution test detector). The detector is used to evaluate the impact of electromagnetic interference above 1GHz on digital communication systems.

4. The APD measurement function defined in CISPR16-1-1

5. It has a variety of standard and optional test accessories, and has touch control and linkage functions to facilitate the accurate execution of the test content required by the standard.

6. It is used to Real-time spectrum analysis for in-depth analysis of disturbance details: PMM 7010 combined with powerful PMM Emission Suite can help people discover and measure electromagnetic disturbance spectrum caused by occasional or short-lived events. Identify intermittent interference from the frequency domain and time domain to speed up the progress of product certification.

7. Strong and durable, compact structure, suitable for on-site or field test applications: due to its small size, light weight (only 4.1kg including battery), built-in lithium battery power supply and other characteristics

8. In addition, PMM 7010 solves the problem of field electromagnetic interference testing for environmental assessment engineers, and develops matching antennas for China's high-level power transmission and transformation systems. It meets the test requirements of the existing 750kV and future 1000kV ultra-high voltage power transmission and transformation projects.

9. No calibration or maintenance required.


Technical Parameters For EMI Test System:


Frequency range: DC-6GHz (the system configuration frequency is determined according to the instrument index)

Input impedance: 50Ω±5Ω (typical value: 50Ω±2Ω)

Voltage standing wave ratio: ≤1.75 (typical value: ≤1.5)

Maximum input power: 1000W

Electric field strength range: 0.01-200V/m (according to the input power)

Cell dimensions of outer: 4.0m x 2.2m x 2.1m (L x W x H)

Maximum electronic partition height: 750mm

±3dB field uniformity test area: 350 mm x 350 mm

Maximum recommended EUT test volume

Maximum recommended EUT test area: 67.5 x 67.5 x 49cm

Approximate cell weight: 500kg


Name of technical parametersContents of technical parameters
Frequency
Frequency range150kHz~1GHz (Opt.00)
9kHz~1GHz (Opt.01)
9kHz~30MHz (Opt.02)
9kHz~3GHz (Opt.03)
Frequency resolution10Hz
Frequency accuracy<3ppm
Rf impute
Port resistanceZin 50Ω
Type of PortN (f)
Port standing wave<1.2 (10dB RF Att), <2.0 (10dB RF Att >1GHz)
<1.2 (0dB RF Att), <1.4 (OdB RF Att >30MHz), <2.0 (0dB RF Att >1GHz)
Attenuation0dB~35dB (5dB step), 0dB~50dB (2dB step >30MHz)
Pulse limiterBuilt-in (Frequency up to 30MHz)
Max input level (equipment not damaged)
Sinusoidal AC voltage140dBµV (2W)
pulse spectrum density100dBµV/MHz
Preselector9kHz~30MHz, 30MHz~1GHz, 1~3GHz

IF Bandwidth

6dB bandwidth: 1kHz (Opt.01, Opt.02, Opt.03), 3/10/30/100/300/1MHz (Opt.03)
6dB bandwidth (CISPR16-1-1): 200Hz (Opt.01, Opt.02, Opt.03), 9kHz, 120kHz
6dB bandwidth (MIL-STD-461): 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz
Noise levelfrequency bandQPeak (dBµy)Average (dBµy)
9~150kHz RBW=200Hz<0 (-130dBm/Hz)<-3 (-133dBm/Hz)

0.15~30MHz

RBW=9kHz

<14 (-128dBm/Hz)<7 (-135dBm/Hz)
0.03~1GHz RBW=120kHz<14 (-144dBm/Hz)<7 (-151dBm/Hz)

1~2.7GHz

RBW=1MHz

<16 (-151dBm/Hz)

2.7~3.0GHz

RBW=1MHz

<19 (-148dBm/Hz)
Main measuring functions (Use with PMM Emission Suite SW software)
Identification, peak identification, center identification, highest peak, moving peak to analysis & manual mode, automatic test report generation
80dB~200dB adjustable dynamic range
Display unit: dBm, dBµy, dBµA, dBµV/m, dBµT, dBµAm, dBpW
Store-Load: traces, panels, correction factors, test limit lines

(S/N>20dB)

Measurement accuracy

9kHz~1GHz: ±1.0dB
1GHz~3GHz: ±1.5dB
Spurious responseAtt 0dB, 50Ω, peak detection, dwell time 10ms: <20dBµV (above 2.7GHz <23dBµV)
DetectorsPeak, Quasi-Peak, Average, RMS, RMS-Average (option), C-Average, Smart Detector function
Level measuring timeCISPR16-1-1 default, 0.2ms~120s
CISPR16-1-1Standards-compliant detector detects signals down to 20Hz PRE
DemodulationBuilt-in AM demodulator, FM demodulator (built-in speaker)
I/O InterfaceUSB2.0, RS-232, user port (drives LISN and other test accessories)
Operating temperature-5°C~45°C
Power supply12Vdc, 0.8A, AC adapter and power cord
Dimensions235mm x 105mm x 335mm
Weight5.0kg
Built-in LISN (conforming to CISPR16-12)
Frequency Range9kHz~30MHz
Working voltage and withstand current250Vac, 350Vdc, <16A
Frequency range of the power supply of the equipment under testDC~60Hz
CISPR equivalent circuit50Ω (5Ω+50µH)
Type of interface for the device under testSchuko cylindrical interface
Connecting plug conform to standardIEC 60320 C20
Artificial hand4mm socket

China CISPR16-1-1 Gigahertz Transverse Electro Magnetic Cell EMI Test System supplier

CISPR16-1-1 Gigahertz Transverse Electro Magnetic Cell EMI Test System

Inquiry Cart 0