IEC 60086-4 Battery Test Equipment Mechanical Abuse Of Cylindrical Cells Impact Test

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN555
Minimum Order Quantity:1
Delivery Time:30 Days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

IEC 60086-4 Battery Test Equipment Mechanical Abuse Of Cylindrical Cells Impact Test


Overview:

Battery impact test equipment is used to test the safety performance of batteries from different heights through different masses and different impact areas. Batteries are qualified if there is no flame or explosion after the impact test.

Standards Compliant:

Comply with IEC 60086-4: 2014 Article 6.5.2 Figure 3, UL1642:2012 Article 14 Figure 14.1, UL 2054, UN38.3, GB/T 18287-2013, GB 31241-2014, GB-31241-2014, QB/T2502 and other standards.

Technical Parameters:

Impact Mass

9.1kg

Impact Height

0~880mm
(The mass can be raised to a height and released to ensure the mass dropping free without inclining and swing)

Control Method

PLC Touch Screen Control+ Remote Control

Crossing Bar Diameter

15.8 mm (Place on central position in cross direction and the heavy bar and steel bar is parallel to battery bottom)

Test Room

W300 X D300 X H300mm

Internal Material

SUS 304# Stainless steel(thickness 1.0mm compensation and external chamber thickness 80mm)

External Material

Cool-Rolled Plate (thickness 1.0mm)

Air Vent

150mm, on the top of back of chamber

Chamber Gate

Single Door, Viewing Window, cold-rolled door lock

Viewing Window Size

390 X 360mm (20mm Dual layer glass explosion proof film)

Elevating Method

Motorized

Top/bottom impact surface

Steel Plate

Chamber Size

W940 X D780 X H1620mm

Power Source

AC 220V, 60Hz

Power

2.0KW

Gross Weight

About 250KG

Touch Screen Monitoring


Test Procedure:

The impact test is applicable to cylindrical cells with a diameter greater than 20 mm.

The test cell or component cell is placed on a flat, smooth surface. A stainless steel bar (Type 316 or equivalent) 15.8 mm ± 0.1 mm in diameter and at least 60 mm in length or the longest dimension of the cell, whichever is greater, is placed across the centre of the test specimen. Using a nearly frictionless vertical sliding rail or hammock, a weight of 9.1 kg ± 0.1 kg is dropped from a height of 61 cm ± 2.5 cm onto the intersection of the bar and the test specimen in a controlled manner, with minimum resistance to the falling weight. The vertical rail or hanger used to guide the falling weight shall be at an angle of 90 degrees to the horizontal support surface.

The longitudinal axis of the test specimen at impact shall be parallel to the plane and perpendicular to the long axis of the stainless steel bar across the centre of the test specimen (see Figure 3).