-70℃ To +150℃ Temperature And Humidity Test Chamber IEC62133 For Battery Test

Brand Name:Sinuo
Certification:Calibration Certificate(Cost Additional )
Model Number:SN559-1000L
Minimum Order Quantity:1
Delivery Time:30 Days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

-70℃ to +150℃ Temperature and Humidity Test Chamber IEC62133 For Battery Test


Product information:


The Temperature and Humidity Test Chamber designed for reliability testing of electronics, electrical components, plastics, and other materials. It complies with international standards such as IEC62133, UN38.3, and IEC60068-2-2:2007. With a temperature range of -70°C to +150°C and humidity control from 20% to 98% RH, it ensures precise simulation of extreme environmental conditions for product validation.


Technical parameters:


Product ModelSN559-1000L
Nominal Volume1000L
Internal DimensionsW1000*H1000*D1000mm
External DimensionsW1280*H2150*D2050MM
WeightApproximately 580KG
Test Environmental ConditionsAmbient temperature: +25℃, relative humidity ≤ 85%, no samples inside the chamber
Temperature Range-70℃ to +150℃
Humidity Range

(20~98)% RH

(Temperature: 20℃~85℃, refer to the temperature-humidity control range chart, without active heat load)

Temperature Fluctuation±0.5℃
Humidity Fluctuation≤2.5%
Temperature Deviation≤±2.0℃
Humidity Deviation≤±3%
Heating Rate-70℃ to +150℃ ≥5℃/min (Average over the entire range)
Cooling Rate+150℃ to -70℃ ≥5℃/min (Average over the entire range)
Load ConditionNone
Operating NoiseA-weighted sound level ≤70 dB(A)
(Measurement taken in a soundproof room with minimal echo at an ambient temperature of 25℃.
Using A-weighting, the average value is measured at 9 points.
Each test point is 1 meter horizontally from the noise source and 1 meter above the ground.)
Structural Features

Thermal Insulation Structure


1.Outer wall material: A3 steel plate with spray coating.

2.Inner wall material: Brushed stainless steel plate SUS#304.

3.Thermal insulation material for the box body: 100mm high-temperature-resistant rigid polyurethane foam.

4.Thermal insulation material for the door: 100mm high-temperature-resistant rigid polyurethane foam.

Bottom Structural StrengthThe bottom of the test chamber is designed with track load-bearing capacity: ≤100kg/m² (load).
Air Conditioning Channel

1.Stainless steel long-shaft centrifugal fan: 2 units, 90W.

2. Fan, heater, evaporator (also dehumidifier), drainage device, pressure balance port, adjustable air guide plate, temperature sensor.

Standard Configuration of the Test Chamber

1.Window: 400x600x40mm, 3 layers of vacuum tempered glass.

2.Embedded flat handle.

3.Door hinge: SUS #304 imported hinge.

4.Internal energy-saving light: LED energy-saving light.

5.Lead hole: φ50mm, 1 unit, located on the right side.

Door

1.Single door, opens outward, hinge on the left, handle on the right (when facing the front of the chamber).

2.Equipped with a safety door lock mechanism (the door can be opened from inside the test chamber). The door is equipped with electric anti-condensation heating, and the hollow glass observation window has a viewing area of approximately (W400×H600mm). The door frame is equipped with anti-condensation electric heating.

Control PanelController with 7-inch display, temperature (humidity) control display, operation indicator light, and lighting button.
Mechanical RoomRefrigeration unit, compressor water tray, pressure relief device, heating device.
Power Distribution CabinetPower distribution board, cooling fan, main power switch, transformer, intermediate relay, time relay, solid-state relay, AC contactor, circuit breaker.
Heater

1.High-quality custom heating wire set.

2.Heating control mode: SSR (solid-state relay), non-contact periodic pulse width modulation.

3.Heating power: approximately 4KW.

Power Line HoleLocated on the back of the chamber.