100TPH RO Water Treatment System For Landfill Leachate Treatment System

Brand Name:Jufu
Certification:ISO9001
Model Number:JFRO-100T
Minimum Order Quantity:1 unit
Delivery Time:2-4 weeks
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Address: 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018
Supplier`s last login times: within 31 hours
Product Details Company Profile
Product Details

100TPH RO Water Treatment System For Landfill Leachate Treatment System


Reverse osmosis (RO) systems are common water purification system devices that use partially permeable membranes to separate ions, unwanted molecules, larger particles and colloid, organic impurities, and heavy metal ions from drinking water. RO water treatment system remove a wide range of dissolved and suspended chemicals and biological substances (mainly bacteria) from water, as well as asbestos, a variety of taste, color and odor producing chemicals, particulates, total dissolved solids, turbidity and radium for industrial processes and drinking water production.


How does RO Water Treatment System Works


The reverse osmosis system is an important part of the water treatment system and is widely used in the preparation of purified water and drinking water. When the RO membrane is on one side of the selective membrane, by applying pressure to the solution, the RO membrane removes many types of macromolecules and ions from the solution. The result is that solutes such as iron, viruses, bacteria and solids are retained on the pressurized side of the membrane, while pure solvent is allowed to pass through the other side of the membrane.

Technical Specifications of
RO Water Treatment System


ModelJFRO-100T
Host Size7200x2000x2200mm (can be customized)
Power110KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure1.2~1.5MPa
Recovery Rate75%
Designed Water Inlet135t/h
Outlet Flow100t/h
Desalination Rate≥99.5%
RO FrameSUS304/Carbon Steel (Optional)
Membrane Size8040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes108
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP(Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingFRP
Number of Membrane housing18
Pipe MaterialU-PVC/ Stainless steel (Optional)

RO Water Treatment System Process Flow:


Source water tank → source water booster pump → multi-media filter → active carbon filter → resin softening device → precision filter → first RO reverse osmosis pure water system → second RO reverse osmosis pure water system → water-gas mixer → ozone sterilizer → stainless steel pure water tank → automatic filling line



Features and Benefits of RO Water Treatment System


1. The system can produce water automatically and continuously.
2. No need for chemical regeneration, easy to operate and maintain.
3. The core components of the reverse osmosis system are the CNP pump and the Vontron reverse osmosis membrane.
4. The pure water tank is automatically opened when the water level is low, and the original water tank is automatically closed when the water level is high.
5. The system will automatically flush the reverse osmosis membrane for about 90s, reducing the membrane fouling speed.
6. Water shortage protection and low pressure protection switch of water pump.
7. The conductivity monitor will continuously detect the water quality online and display the data.
8. The whole system adopts water flow meter, pressure gauge, solenoid valve, regulating control valve and control panel.
9. The reverse osmosis controller makes the whole reverse osmosis system run automatically.
10. Easy to control and maintain.


Application fields of RO Water Treatment System


1. Purification of purified water, distilled water, food and beverage water.
2. Preparation of pure water and ultrapure water in electronics, medicine, food and other industries.
3. Process engineering for separation, concentration and liquid decolorization in light textile, chemical, food and other industries.
4. Desalination of sea water and brackish water


Photos of RO Water Treatment System









FAQ:


1. What are the inlet water quality requirements for ro water treatment system membrane components?



Items

NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
Limits≤1≤5≤4≤3

2. What is the material of ro water treatment system membrane?


Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis


Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.


3. RO water treatment system configuration:


First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1


Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.


The arrangement of membrane components can be divided into series and parallel.

China 100TPH RO Water Treatment System For Landfill Leachate Treatment System supplier

100TPH RO Water Treatment System For Landfill Leachate Treatment System

Inquiry Cart 0