Product Introduction of RO Water Treatment System
Host part of reverse osmosis equipment
The reverse osmosis sewage purification equipment server is mainly
composed of a multi-media filter, a high-pressure pump, a reverse
osmosis membrane, and various controls and digital display
instruments.
Multi-media filter: The multi-media filter is the last line of
maintenance before the source water enters the membrane. It is
capable of properly removing pre-solvent spilled chemicals greater
than 5 µm. The main purpose is to prevent floating particles from
entering the reverse osmosis membrane components, accumulating on
the surface of the membrane and polluting the membrane components.
a. High-pressure pump: provide the required working pressure for
reverse osmosis, and ensure the separation of the organic solvent
and the concentration of the substance. High pressure pump is one
of the core components of reverse osmosis equipment.
b. Reverse osmosis membrane group: The reverse osmosis membrane
group is composed of aggregated fibers with a well-ordered drainage
matrix structure. Its diameter is 1-10 angstroms, that is, one ten
billionth of a meter to one billionth of a meter (equivalent to one
six thousandth of the size of Escherichia coli and one three
thousandth of a virus infection). The separation characteristics of
the reverse osmosis membrane can effectively remove the residues
such as molten salts, colloidal solutions, organic compounds, heavy
metals exceeding the standard, and chlorine disinfection, such as
trihalomethane gas chemical intermediates, germs, and microbial
strains in organic solvents.
c. Reverse osmosis membrane shell: It is used to accommodate
reverse osmosis membrane components, bear pressure and form a
high-pressure environment for reverse osmosis operation.
d. Steam flowmeter: The pure water steam flowmeter and concentrated
water flowmeter can accurately measure the total flow of RO pure
water, concentrated water and time respectively.
e. Barometer: Accurately measure the pressure in various places of
the reverse osmosis equipment.
f. Concentrated water control valve: used to adjust the operating
pressure of RO equipment, the proportion of pure water and
concentrated water, and the output of pure water.
g. Conductivity meter: detect the conductivity of pure water
produced by reverse osmosis.
h. Low-voltage switch: Prevent the RO high-pressure pump from
working at high speed or working at low voltage beyond the limit.
e. Water level controller: automatically shut down or run the
reverse osmosis equipment through the liquid level gauges of the
source water tank and pure water tank.
i. Electronic control system: including instrumentation equipment
such as conductivity meter and control system, it is the monitoring
center of reverse osmosis equipment.
Advantages of RO water treatment system:
Technical Features:
1. American ultra-low pressure roll-type composite reverse osmosis
membrane with high desalination rate and low operating pressure,
excellent water quality, low operating cost and long service life;
2. High-efficiency, low-noise, high-quality high-pressure pumps;
3. The online product water conductivity meter can monitor the
water quality at any time;
4. The product water and concentrated water are equipped with flow
meters to monitor the water output and recovery rate of the system;
5. Pressure gauges before and after the fine filter, and pressure
gauges before and after the reverse osmosis membrane can
continuously monitor the pressure difference between the reverse
osmosis membrane and the fine filter, prompting when to clean or
replace;
6. The high pressure switch protects the reverse osmosis membrane
from damage due to excessive pressure;
7. The low-pressure switch protects the high-pressure pump from
damage due to water supply stop;
8. The stainless steel regulating valve adjusts the water output
and the system recovery rate at any time;
9. The standard program automatic control system can reduce the
membrane fouling speed, prolong the service life of the membrane,
and ensure the stable and reliable water quality of the system
effluent.
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter
(quartz sand filter) → Activated carbon filter → Soft water
processor → Precision filter → High pressure pump → Primary reverse
osmosis (RO) device → Purified water tank → High pressure pump →
Two Stage reverse osmosis → ultraviolet sterilization device →
water point.
Photos of Reverse Osmosis Water Treatment System
FAQ:
1. What is the design water yield of ro membrane element? (except
anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3.What are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and
softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean
source, etc.