

Add to Cart
Hot Selling 500lph Mini Ro Water Treatment Plant Water Purification
System 500lph
Product Introduction of RO Water Treatment System
Welcome to the introduction of the new reverse osmosis water purification machine of JUFU. This is the new model that we mainly launched in the latest year.
The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to
a pressure of 6-20 kg, the raw water permeates through the reverse
osmosis membrane with a pore size of only 0.0001 microns under the
action of pressure. Chemical ions, bacteria, fungi, and virions
cannot pass through, and are discharged with wastewater. Only water
molecules and solvents with a volume of less than 0.0001 microns
are allowed to pass through.
Technical Specifications of RO Water Treatment System
500LPH Reverse Osmosis System | |
Model | JFRO-500L |
Host Size | 800x600x1600mm (can be customized) |
Power | 1.5KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 50% |
Designed Water Inlet | 1000L/h |
Outlet Flow | 500L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 4040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 2 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP (Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | SS/FRP (Optional) |
Pipe Material | U-PVC, Stainless steel (Optional) |
Application fields of RO water treatment system
Water treatment system treat raw water in several procedures in
order to meet the bottled drinking water standard.
This system uses water pressure pump to increase the water supply
pressure; sand filter is used to remove Plankton, Moss, Suspension,
Colloid and so on. Active carbon filter is used to remove strange
smell, chlorine, chloride, organic matter and heavy mental, lower
color and optimize water quality. Sodium softer is used to remove
the calcium and magnesium ions in water. Micro filter is used to
remove the tiny impurity. Hollow fiber Ultra filter can remove
impurity, colloid, phenolic compounds, chloride, germ and all the
harmful substance, meanwhile keep all beneficial minerals in water.
Reverse osmosis can move all the things in the water and to make
raw water to be pure water.
Advantages of reverse osmosis:
Continuous operation, stable product water quality
No need for acid-base regeneration
No downtime for regeneration
Saves water for backflushing and cleaning
Produce ultrapure water at high yields (yields can be as high as
95%)
No regenerated sewage, no need for sewage treatment facilities
No need for acid-base storage and acid-base dilution transport
facilities
Reduce the building area of the workshop
It is safe and reliable to use, preventing workers from contacting
acid and alkali
Reduce operation and maintenance costs
Simple installation and low installation cost
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter
(quartz sand filter) → Activated carbon filter → Soft water
processor → Precision filter → High pressure pump → Primary reverse
osmosis (RO) device → Purified water tank → High pressure pump →
Two Stage reverse osmosis → ultraviolet sterilization device →
water point.
Photos of reverse osmosis water treatment system
FAQ:
1. What is the design water yield of ro membrane element? (except
anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3.What are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and
softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean
source, etc.