Commercial Drinking Water Treatment System 500LPH Mini Ro Plant Purification

Brand Name:Jufu
Certification:ISO9001
Model Number:JFRO-500L
Minimum Order Quantity:1 unit
Delivery Time:2-4 weeks
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Address: 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018
Supplier`s last login times: within 31 hours
Product Details Company Profile
Product Details

500LPH Commercial Mini Ro Plant Purification Water Treatment Systems Filter System

Product Introduction of RO Water Treatment System


Reverse Osmosis Technology is a modern high technology developed recently in China. Reverse osmosis is to separate water from solution after it permeates the specially-made semi-transparent membrane through exerting a pressure that is higher than the osmosis pressure on the solution. As this process is reverse to the natural permeation direction, it is called reverse osmosis. According to different osmosis pressures of various materials, the process of reverse osmosis with a pressure higher than the osmosis pressure can be used to reach the purposes of separation, extraction, purification and concentration of a certain solution. It dose not need heating and there is no phase changing process; therefore, it saves more energy than traditional process.


The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.

Technical Specifications of RO Water Treatment System

500LPH Reverse Osmosis System
ModelJFRO-500L
Host Size800x600x1600mm (can be customized)
Power1.5KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet1000L/h
Outlet Flow500L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes2
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)

























Application fields of RO water treatment system
Water treatment system treat raw water in several procedures in order to meet the bottled drinking water standard.
This system uses water pressure pump to increase the water supply pressure; sand filter is used to remove Plankton, Moss, Suspension, Colloid and so on. Active carbon filter is used to remove strange smell, chlorine, chloride, organic matter and heavy mental, lower color and optimize water quality. Sodium softer is used to remove the calcium and magnesium ions in water. Micro filter is used to remove the tiny impurity. Hollow fiber Ultra filter can remove impurity, colloid, phenolic compounds, chloride, germ and all the harmful substance, meanwhile keep all beneficial minerals in water. Reverse osmosis can move all the things in the water and to make raw water to be pure water.


Advantages of reverse osmosis:
Continuous operation, stable product water quality
No need for acid-base regeneration
No downtime for regeneration
Saves water for backflushing and cleaning
Produce ultrapure water at high yields (yields can be as high as 95%)
No regenerated sewage, no need for sewage treatment facilities
No need for acid-base storage and acid-base dilution transport facilities
Reduce the building area of the workshop
It is safe and reliable to use, preventing workers from contacting acid and alkali
Reduce operation and maintenance costs
Simple installation and low installation cost


Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.



Photos of reverse osmosis water treatment system










FAQ:

1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)

Model 4040 is designed by 0.25m3/h

Model 8040 is designed by 1-1.2m3/h

2. What is the material of mechanical filter?

Carbon steel, stainless steel, fiberglass

3.What are the multi-way control valves?

Manual control valve, automatic control valve

Multi - way control valve is divided into: filter valve and softening valve

Automatic control valve is divided into: time type and flow type.

Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

China Commercial  Drinking Water Treatment System 500LPH Mini Ro Plant Purification supplier

Commercial Drinking Water Treatment System 500LPH Mini Ro Plant Purification

Inquiry Cart 0