HPV Genotype 2+12 High Risk 16+18 Medium Risk PCR Detection Kit 96 Tests/Kit

Brand Name:Biokey
Certification:CE
Model Number:BIK-QL-H0018
Minimum Order Quantity:We can produce liquid and lyophilized kits
Delivery Time:Depending on order quantity
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou
Address: Add:No.2, Ruitai Rd, Guangzhou Hi-Tech Industrial Development Zone, 510670, CHINA
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

HPV Genotype 2+12 High risk(16+18)+Medium risk Real Time PCR Detection Kit (Lyophilized) --96 tests/kit


Intended use:

This kit, adopting Real-Time PCR-Fluorescence technology, is used for qualitative detection of 14 types of HPV(16, 18, 31, 33,
35, 39, 45, 51, 52, 56, 58, 59, 66, 68). It can be used for the laboratory diagnosis and monitoring of the virus infection. The test results are only for clinical reference, not for case confirmation or exclusion.


Principle:

The specific primers and specific fluorescent probes are designed for the conserved region of HPV(16, 18, 31, 33, 35, 39,
45, 51, 52, 56, 58, 59, 66, 68). The PCR reaction solution, and real-time fluorescent quantitative PCR detection technology is applied on the fluorescence quantitative PCR instrument to realize the rapid detection of HPV through the change of fluorescence signal. The detection system contains a human internal control (IC) gene, which is used to monitor whether the specimens and the process of the nucleic acid extraction is qualified.


NG product lyophilization pacakage:



Main components:

No.

Components

BIK-QL-H0018

1

PCR Enzyme Mix (Lyophilized)

96 tests/kit

2Positive Control

100 μL/tube

3Negative Control

100 μL/tube

4Dilution Solution1mL/tube
5Paraffin oil1.6mL/tube


Note: Do not mix the components from different batches for detection. The Positive Control of HPV and internal control were constructed artificially, and they were not infectious.



Specimen requirements:

1.Specimen type :
Cervical shedding cells, genitourinary tract secretions.

2.Specimen collection and transportation:
Clean the sampling site with sterile saline, and then use an epithelial brush (cervical brush, swab, etc.) to collect exfoliated cells from the cervix or genitourinary tract, epithelial cells at the lesion, secretions, etc. swabs, etc.) into a sterile storage tube and seal it for inspection.

3.Specimen preservation:
The specimen can be stored for 2 weeks at 4-8℃, 3 months at -20±5℃ and for a long time below -70℃.



Quality control:


Negative Control: None of the FAM, VIC/HEX, ROX& Internal Control (CY5) channels have a Ct value or Ct >38;

Positive Control: FAM, VIC/HEX, ROX& Internal Control (CY5) channels Ct ≤ 30;

The above two items should be met simultaneously in one experiment. Otherwise, the experiment is invalid and should be repeated.

Data analysis and interpretation:

The following sample results are possible:

Ct valueResult Analysis
1#No Ctnegative
2#≤38Positive
3#38~40Re-test; if it is still 38~40, report as 2#

Interpretation of test results:

FAM (12 High-risk

HPV types)

VIC/HEX

(HPV 16)

ROX

(HPV 18)

CY5(IC)

Interpretation test

results


1


-


-


-


-

Result invalid,test

again


2


+


-


-


+/-

12 High-risk HPV types(+)

3-+-+/-HPV 16(+)
4--++/-HPV 18(+)

5


+


+


-


+/-

12 High-risk HPV

types, HPV 16(+)


6


+


-


+


+/-

12 High-risk HPV

types, HPV 18(+)

7-+++/-HPV16+18(+)
8++++/-

12 High-risk HPV

types, HPV16+18(+)

9---+

Negative(-)


NOTE: ‘+’ is positive, ‘-’ is negative.


Operation details please check from IFU!

China HPV Genotype 2+12 High Risk 16+18 Medium Risk PCR Detection Kit 96 Tests/Kit supplier

HPV Genotype 2+12 High Risk 16+18 Medium Risk PCR Detection Kit 96 Tests/Kit

Inquiry Cart 0