IC6200 PEEK Pump Ion Exchange Chromatography Instrument for Anions or Cations Analysis

Brand Name:Wayeal
Certification:ISO, CE
Model Number:IC6200
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

IC6200 PEEK Pump Ion Exchange Chromatography Instrument for Anions or Cations Analysis


Introduction of Ion Chromatography Instrument

Ion chromatography instrument is a kind of high performance liquid chromatography, so it is also called high performance ion chromatography (HPIC) or modern ion chromatography. It is different from traditional ion exchange column chromatography mainly because that resin has high cross-linking degree and low exchange capacity, the sample volume is very small, and normally, a plunger pump is used to pump eluent for on-line automatic continuous conductivity detection of leachate.


Features of Ion Chromatography Instrument

1. Intergrated design, LCD full touch GUI controller
2. High degree of automation, one key flushing, one key maintenance
3. Higher integration: support optional parts upgrade to 2D system and multi-detector coupling.
4. All-plastic non-metallic flow path.
5. Highly precise temperature control for the whole system.
6. Precision PEEK material ion chromatography pump.
7. Electrolytic self-regenerating membrane suppressor.
8. High-precision temperature-controlled conductivity detector.
9. Powerful and easy-to-use chromatography workstation.


Parameters of Ion Chromatography Instrument

IC6200 PEEK Pump Ion Exchange Chromatography Instrument for Anions or Cations Analysis
System Parameter
Qualitative Repeatability≤0.5%
Quantitative Repeatability≤1%
Pump System
Flow Rate(0.001~10.000)mL/min
Pump Head Pressure Resistance(0 ~ 35) Mpa
Flow Rate Setting Inaccuracy<0.1%
Flow Stability<0.1%
Pressure Display Accuracy0.01Mpa
Pressure Pulsation<0.5%
Conductivity Detector
Baseline Noise≤0.1%FS
Baseline Drift≤0.5%FS
Minimum Detectable Concentration (Cl)≤0.0002μg/mL
Minimum Detection Concentration (Li)≤0.0001μg/mL
Conductivity Cell Volume≤ 0.6μL
Conductivity Detection Range0-15000μS/cm
Detector Resolution0.00238nS/cm
Conductivity Cell Temperature Setting Error±0.01°C
Resolution of Conductivity Cell Temperature Display0.001°C
Suppressor
Constant Current Source Range0-500mA in 0.1mA increments
Column Oven
Temperature RangeRoom temperature +5°C~85°C
Control Temperature Stability≤ 0.1°C
Autosampler
Number of Sample Vials≥ 120 (1.5mL standard sample bottle)
Repeatability

Full loop injection < 0.3% RSD,

Partial injection < 0.5% RSD,

Non-destructive injection < 1 % RSD (injection volume > 5μL)

Syringe SizeStandard: 500μL; optional; 250μL, 1000μL, 2500μL
Loop SizeStandard: 100μL; optional: 20μL, 50μL, 200μL
Linearity>0.999
Cross-contamination<0.01%
Eluent Generator
Flow Rate Range0.001 to 3.000mL/min
Eluent Concentration RangeKOH, MSA-0.1 to 100mM
Concentration Accuracy0.1mM
Original Concentration of Electrolyte25% KOH/MSA
Volume of Electrolyte1000mL
Maximum Working Pressure21Mpa (3000psi)
Gradient Accuracy1.5%