Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis

Brand Name:Wayeal
Certification:ISO, CE
Model Number:AA2300
Minimum Order Quantity:1
Delivery Time:30 days
Place of Origin:Anhui, China
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Double Beam Graphite AAS Atomic Absorption Spectrometer for Metal Analysis

Introduction of Atomic Absorption Spectrophotometer
Atomic absorption spectrophotometer will be used to analyzes metal elements according to the effect of atomic vapor in the ground state of matter on characteristic radiation absorption, and it can sensitively and reliably determine minor or trace elements.

Parameters of Atomic Absorption Spectrophotometer AA2300

Double Beam Graphite AAS Atomic Absorption Spectrometer for Metal Analysis

Wavelength range(nm)

185-900nm

Wavelength indication error(nm)

±0.15nm

Wavelength repeatability(nm)

≤0.05 nm

Spectral Bandwidth

0.1, 0.2, 0.4, 1.0, and 2.0nm

Zero Drift

±0.002/30min

Instantaneous noise(Abs)

≤0.002 Abs

Flame Atomizer


Detection limit

Cu: ≤0.002μg/mL

Repeatability

RSD≤0.25%

Graphite Furnace Atomizer


Detection limit(Graphite Furnance: Cd pg)

≤0.3pg

Repeatability

RSD≤1.5 %

Heating temperature

room temperature -3000°C or so

Heating rate

3000°C/s

Autosampler


Injection bits108
Linear>0.999
Injection volume1-200μL
Injection volume repeatability≤0. 1%
Result repeatability≤1.5%
Background correctionDeuterium lamp
Lamp position8


Features of Atomic Absorption Spectrophotometer AA2300
1. An 8-lamp holder design alows for simultaneous i lumination or preheating to cater to a broader range of customer needs
2. Newly developed software modules oer a user-friendly inte ace with high automation, ensuring improved human-computer interaction
3. A Graphite Furnace Visualization System enhances convenience in conguring the autosampler while concurrently monitoring variations in each temperature stage of the sample
4. Optical Dual-Beam System

5. 8-Lamp Holder Design

6. Parallel Dual Atomization System Design

Applications of Atomic Absorption Spectrophotometer
Because of its high sensitivity, less interference, simple and rapid analysis method, atomic absorption spectrophotometer is now widely used in industry, agriculture, biochemistry, geology, metallurgy, food, environmental protection, etc. At present, atomic absorption has become one of the powerful tools for the analysis of metal elements, and it has been used as a standard analytical method in many fields.


China Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis supplier

Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis

Inquiry Cart 0